Evidence map›Paper›PMID 39568447›Full record

ArticleJournal of experimental orthopaedics2024

Radiographic acceptable zone of endobutton placement in ACL reconstruction: A prospective study.

Arash Sharafatvaziri, Mohammad Tahami, Maryam Salimi, Hamid Rabie, Fardis Vosoughi, Morad Karimpour, Ghazaleh Moradkhani, Mosayeb Soleymani

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Arash SharafatvaziriDepartment of Orthopedic Surgery Shariati Hospital Tehran Iran.
Mohammad TahamiDepartment of Orthopedic Surgery Chamran Hospital Shiraz Iran.
Maryam SalimiDepartment of Orthopedic Surgery School of Medicine, Chamran Hospital Shiraz University of Medical Sciences Shiraz Iran.
Hamid RabieCenter for Orthopedic Trans-Disciplinary Applied Research Tehran University of Medical Sciences Tehran Iran.
Fardis VosoughiDepartment of Orthopedic Surgery Shariati Hospital Tehran Iran.
Morad KarimpourDepartment of Mechanical Engineering College of Engineering, University of Tehran Tehran Iran.
Ghazaleh MoradkhaniDepartment of Mechanical Engineering College of Engineering, University of Tehran Tehran Iran.ORCID 0000-0002-5145-4235
Mosayeb SoleymaniCenter for Orthopedic Trans-Disciplinary Applied Research Tehran University of Medical Sciences Tehran Iran.ORCID 0000-0001-7419-3536

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: During the transportal technique of anterior cruciate ligament (ACL) reconstruction, tunnel outlet location can be varied depending on certain anatomical and technical characteristics. Therefore, we aimed to find out the acceptable zone of endobutton location by introducing several radiographic values. Methods: Postoperative lateral radiographs of 72 patients were assessed to measure the distances from the centre of the button to the posterior femoral cortex (D1) and to the most distal point of the lateral condyle (D2). Furthermore, based on the anteroposterior (AP) radiographs, the distances from the centre of the button to the lateral femoral cortex (D3) and from the centre of the button to the line connecting the most distal points of the medial and lateral femoral condyles (D4) were assessed. To measure the sensitivity and specificity of each radiographic value (D1, D2, D3 and D4), the area under the receiver operating characteristic curve was calculated. The alpha angle and femoral tunnel length values were considered as gold standards. Results: Analyses showed that the mean values for D1, D2, D3 and D4 were 13.20 ± 0.54, 39.44 ± 0.31, 1.65 ± 0.15 and 42.66 ± 0.47 mm, respectively. The mean angle was found to be 38.6 ± 0.3°, and the mean femoral tunnel length was 38.6 ± 0.2 mm. Age was significantly related to D2 and the diameter of the femur in AP X-ray, while body mass index had a significant relation with D3 ( Conclusion: In this study, a new method was proposed to evaluate the accuracy of anatomical tunnel placement in ACL reconstruction surgery postoperatively. The statistical analysis of the measured variables showed that the mean ratios were 21.79 ± 0.87 for D1, 65.65 ± 0.63 for D2 and 51.90 ± 0.73 for D4. The results indicated that if the tunnel exit location and endobutton placement in the postoperative radiological images fall within the suggested areas, it can be meaningfully concluded that the tunnel is correctly positioned intraarticularly and the ligament reconstruction is anatomical. Level of Evidence: Level III.

Indexed as

ACL reconstructionarthroscopy, endobuttonfemoral tunnelplain radiograph

Identifiers

PMID39568447
PMCPMC11577290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.