Evidence map›Paper›PMID 39565820›Full record

ArticlePloS one2024

A cost-effective load side management solution based on power line carrier communication i-PLCC.

Maria Ashraf, Abdul Rafay Khan, Syed Sajjad Haider Zaidi, Asif Gulraiz, Bilal Muhammad Khan

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maria AshrafDepartment of Electronic and Power Engineering, National University of Sciences and Technology, Karachi, Pakistan.ORCID 0000-0001-6475-4870
Abdul Rafay KhanDepartment of Electronic and Power Engineering, National University of Sciences and Technology, Karachi, Pakistan.
Syed Sajjad Haider ZaidiDepartment of Electronic and Power Engineering, National University of Sciences and Technology, Karachi, Pakistan.ORCID 0000-0002-4033-4510
Asif GulraizDepartment of Electronic and Power Engineering, National University of Sciences and Technology, Karachi, Pakistan.
Bilal Muhammad KhanDepartment of Electronic and Power Engineering, National University of Sciences and Technology, Karachi, Pakistan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Conventional power systems are almost at the verge of their existence and are quickly being replaced by modern, especially smarter alternatives. Rapid and wide deployment of Load side management, which is a smarter and modern way to ensure efficient and economical use of power, is a classic example. However, there are several challenges which need to be addressed before it can be realized as a commercially viable solution. Suitable communication method, called "Home Area Networks", is a mandatory requirement which should be cost effective, robust and with ability to simultaneously handle large number of devices. Due to various inherent issues, communication protocols commonly used now-a-days, are not fully capable to address the requirements of HANs. Power Line Carrier Communications (PLCC) can be a suitable and efficient alternative of quick realization of HANs. In this paper, various aspects of PLCC have been analyzed for use in HANs. Modulation methods, materials, physical parameters and effect of noise have been analyzed. The paper evaluates performance and effectiveness of FSK modulation with aluminum transmission medium for PLC within a residential environment, focusing on the tradeoffs between distance, transmission medium diameter, and type of transmission medium, and cable gauge, which can degrade the performance of PLCC. A novel simulation model has been presented incorporating RLCG (Resistance, Inductance, Capacitance, and Conductance) tools and additive white Gaussian noise (AWGN). Performance parameter have been comprehensively analyzed of implementation using aluminum as a communication medium. This paper discusses cost effectiveness of PLCC by replacing copper by aluminum as the transmission medium. The study reveals that aluminum cables must be twice the size of copper cable in order to achieve same communication distances. Higher carrier frequencies in FSK modulation increase noise susceptibility, consequently reducing achievable communication distances. Cables with smaller diameters results in lower transmission ranges. These results highlight the trade-offs involved in implementing FSK for in-home PLCC (iPLCC). The study highlights how crucial it is to take these trade-offs into account while developing and refining FSK-based iPLCC systems for use in smart homes.

Indexed as

Cost-Benefit AnalysisElectric Power SuppliesWireless Technology

Identifiers

PMID39565820
PMCPMC11578503

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.