Evidence map›Paper›PMID 39564692›Full record

ArticleAdvanced materials (Deerfield Beach, Fla.)2024

Ultrasensitive Detection of Chemokines in Clinical Samples with Graphene-Based Field-Effect Transistors.

David Kaiser, Nikolaus Meyerbroeker, Werner Purschke, Simone Sell, Christof Neumann, Andreas Winter, Zian Tang, Daniel Hüger, Christian Maasch, Lucas Bethge and 6 more

Abstract read
In one paragraph

Article in Advanced materials (Deerfield Beach, Fla.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Self-Assembly of Linear Three-Ring Aromatic Thiols on Au(111).The journal of physical chemistry letters · 2026
    Article
  4. Materials and System Design for Self-Decision Bioelectronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  5. Article
  6. Article
  7. Carborane Nanomembranes.ACS nano · 2025
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

David KaiserInstitute of Physical Chemistry, Friedrich Schiller University Jena, 07743, Jena, Germany.ORCID 0000-0001-7455-2172
Nikolaus MeyerbroekerCNM Technologies GmbH, 33609, Bielefeld, Germany.ORCID 0000-0002-2472-5714
Werner PurschkeNOXXON Pharma AG, 10589, Berlin, Germany.
Simone SellAPTARION Biotech AG, 10589, Berlin, Germany.
Christof NeumannInstitute of Physical Chemistry, Friedrich Schiller University Jena, 07743, Jena, Germany.ORCID 0000-0002-3598-7656
Andreas WinterInstitute of Physical Chemistry, Friedrich Schiller University Jena, 07743, Jena, Germany.
Zian TangInstitute of Physical Chemistry, Friedrich Schiller University Jena, 07743, Jena, Germany.ORCID 0000-0003-0134-5273
Daniel HügerInstitute of Physical Chemistry, Friedrich Schiller University Jena, 07743, Jena, Germany.
Christian MaaschNOXXON Pharma AG, 10589, Berlin, Germany.
Lucas BethgeNOXXON Pharma AG, 10589, Berlin, Germany.ORCID 0000-0001-9779-3251
Thomas WeimannPhysikalisch-Technische Bundesanstalt, 38116, Braunschweig, Germany.
Gerben FerwerdaLaboratory of Medical Immunology, Radboud University Medical Center, Nijmegen, 6525 GA, The Netherlands.
Marien I de JongeLaboratory of Medical Immunology, Radboud University Medical Center, Nijmegen, 6525 GA, The Netherlands.ORCID 0000-0003-2812-5895
Albert SchniedersCNM Technologies GmbH, 33609, Bielefeld, Germany.ORCID 0000-0002-0931-3682
Axel VaterNOXXON Pharma AG, 10589, Berlin, Germany.ORCID 0000-0003-4166-982X
Andrey TurchaninInstitute of Physical Chemistry, Friedrich Schiller University Jena, 07743, Jena, Germany.ORCID 0000-0003-2388-1042

Funding

Bundesministerium für Wirtschaft und Klimaschutz 2163 BR / FE2Europäischer Sozialfonds 2020 FGR 0051H2020 European Research Council 634415
6 · The paper itself

Abstract

Due to their ultra-high sensitivity, solution-gated graphene-based field-effect transistors (SG-GFET) have been proposed for applications in bio-sensing. However, challenges regarding the functionalization of GFETs have prevented their applications in clinical diagnostics so far. Here GFET sensors based on van der Waals (vdW) heterostructures of single-layer graphene layered with a molecular ≈1 nm thick carbon nanomembrane (CNM) are presented. The CNM acts as an ultrathin molecular interposer between the graphene channel and the analyte and allows bio-functionalization without impairing the graphene properties including its charge carrier mobility. To achieve specificity and reliability in the detection of biomarkers in real patient samples, the functionalization incorporates biostable aptamers in the non-natural l-configuration and hydrophilic polyethylene glycol for avoiding non-specific adsorption. A rapid (≈5 min) detection of the clinically relevant inflammatory mediator CXCL8/IL-8 within the concentration range of 0.5 - 500 pM (5 - 5000 pg ml

Indexed as

Biosensing TechniquesGraphiteTransistors, ElectronicAptamers, NucleotideChemokinesHumansInterleukin-8Limit of DetectionAptamers, NucleotideChemokinesGraphiteInterleukin-8biosensorscarbon nanomembranesgraphenesolution‐gated field‐effect transistorsvan der Waals heterostructures

Identifiers

PMID39564692
PMCPMC11681312

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.