ArticleShi yan li xue = Journal of experimental mechanics2021
Tricuspid chordae tendineae mechanics: Insertion site, leaflet, and size-specific analysis and constitutive modelling.
Article in Shi yan li xue = Journal of experimental mechanics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure.Annals of biomedical engineering · 2026Article
- Tricuspid valve leaflet remodeling in sheep with biventricular heart failure: A comparison between leaflets.Acta biomaterialia · 2025Article
- Impact of tricuspid annuloplasty device shape and size on valve mechanics-a computational study.JTCVS open · 2024Article
- The impact of thickness heterogeneity on soft tissue biomechanics: a novel measurement technique and a demonstration on heart valve tissue.Biomechanics and modeling in mechanobiology · 2023Article
- Can machine learning accelerate soft material parameter identification from complex mechanical test data?Biomechanics and modeling in mechanobiology · 2023Article
- An introduction to the Ogden model in biomechanics: benefits, implementation tools and limitations.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2022Article
- Texas TriValve 1.0 : a reverse‑engineered, open model of the human tricuspid valve.Engineering with computers · 2022Article
- Biomechanical phenotyping of minuscule soft tissues: An example in the rodent tricuspid valve.Extreme Mechanics Letters · 2022Article
- Article
- Tricuspid Valve Annuloplasty Alters Leaflet Mechanics.Annals of biomedical engineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Background: Tricuspid valve chordae tendineae play a vital role in our cardiovascular system. They function as "parachute cords" to the tricuspid leaflets to prevent prolapse during systole. However, in contrast to the tricuspid annulus and leaflets, the tricuspid chordae tendineae have received little attention. Few previous studies have described their mechanics and their structure-function relationship. Objective: In this study, we aimed to quantify the mechanics of tricuspid chordae tendineae based on their leaflet of origin, insertion site, and size. Methods: Specifically, we uniaxially stretched 53 tricuspid chordae tendineae from sheep and recorded their stress-strain behavior. We also analyzed the microstructure of the tricuspid chordae tendineae based on two-photon microscopy and histology. Finally, we compared eight different hyperelastic constitutive models and their ability to fit our data. Results: We found that tricuspid chordae tendineae are highly organized collageneous tissues, which are populated with cells throughout their thickness. In uniaxial stretching, this microstructure causes the classic J-shaped nonlinear stress-strain response known from other collageneous tissues. We found differences in stiffness between tricuspid chordae tendineae from the anterior, posterior, or septal leaflets only at small strains. Similarly, we found significant differences based on their insertion site or size also only at small strains. Of the models we fit to our data, we recommend the Ogden two-parameter model. This model fit the data excellently and required a minimal number of parameters. For future use, we identified and reported the Ogden material parameters for an average data set. Conclusion: The data presented in this study help to explain the mechanics and structure-function relationship of tricuspid chordae tendineae and provide a model recommendation (with parameters) for use in computational simulations of the tricuspid valve.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.