ArticleCureus2024
Quantifying Radiation Exposure in Minimally Invasive Spinal Surgery: A Single-Surgeon Study of Minimally Invasive Surgery-Oblique Lateral Lumbar Interbody Fusion (MIS-OLLIF) With Double C-Arm Technique.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the advancement of spinal surgery, minimally invasive techniques such as the oblique lateral lumbar interbody fusion (OLLIF) have emerged, offering improved clinical outcomes and the use of dual C-Arm intraoperative imaging. Despite the benefits, the radiation exposure to surgeons and staff from this dual-source imaging has not been thoroughly examined. This study aims to quantify the radiation exposure received by surgeons during OLLIF procedures, filling a gap in current research that primarily focuses on single-source imaging. Over 12 months, radiation doses were measured across 121 surgeries at four locations. Data analysis included average radiation exposure per surgery and variations across surgical sites. The findings showed an average radiation emission of 198.78 mGy per OLLIF surgery, with the surgeon receiving approximately 0.06 mSv per surgery. Cumulative doses for the surgeon were below the safety thresholds set by European and American standards. The significance of these findings lies in their contribution to the understanding of occupational safety in spinal surgery. The results indicate that with proper protective measures, such as lead aprons, the radiation exposure from the OLLIF technique is manageable within occupational limits. This study highlights the importance of monitoring radiation exposure and may influence the development of new guidelines and protective strategies in the field. Future research could expand the cohort of surgeons to validate these findings, develop new protective strategies, and explore radiation exposure in more complex multi-level fusions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.