ArticleDento maxillo facial radiology2025
Gray values and noise behavior of cone-beam computed tomography machines-an in vitro study.
Article in Dento maxillo facial radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo systematically evaluate the mean gray values (MGVs) and noise provided by bone and soft tissue equivalent materials and air imaged with varied acquisition parameters in 9 cone-beam computed tomography (CBCT) machines.
methodsThe DIN6868-161 phantom, composed of bone and soft tissue equivalent material and air gap, was scanned in 9 CBCT machines. Tube current (mA) and tube voltage (kV), field of view (FOV) size, and rotation angle were varied over the possible range. The effect of the acquisition parameters on the MGV and contrast-to-noise indicator (CNI) was analyzed by Kruskal Wallis and Dunn-Bonferroni tests for each machine independently (α = 0.05).
resultsTube current did not influence MGV in most machines. Viso G7 and Veraview X800 presented a decrease in the MGV for increasing kV. For ProMax 3D Max and X1, the kV did not affect the MGV. For the majority of machines, MGV decreased with increasing FOV height. In general, the rotation angle did not affect the MGV. In addition, CNI was lower with lower radiation and large FOV and did not change from 80 kV in all machines.
conclusionsThe MGV and noise provided by the tested phantom vary largely among machines. The MGV is mainly influenced by the FOV size, especially for bone equivalent radiodensity. For most machines, when the acquisition parameters affect the MGV, the MGV decrease with the increase in the acquisition parameters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.