Evidence map›Paper›PMID 39558598›Full record

ArticleAcute and critical care2024

Striving for excellence in ventilator bundle compliance through continuous quality improvement initiative in the intensive care unit of a tertiary care hospital in India.

Naveen Paliwal, Pooja Bihani, Rishabh Jaju, Sadik Mohammed, Prabhu Prakash, Vidya Tharu

Abstract read
In one paragraph

Article in Acute and critical care, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Naveen PaliwalDepartment of Anesthesiology, Dr. S.N. Medical College, Jodhpur, India.
Pooja BihaniDepartment of Anesthesiology, Dr. S.N. Medical College, Jodhpur, India.
Rishabh JajuDepartment of Anesthesiology, All India Institute of Medical Sciences, Deoghar, India.
Sadik MohammedDepartment of Anesthesiology, All India Institute of Medical Sciences, Jodhpur, India.
Prabhu PrakashDepartment of Microbiology, Dr. S.N. Medical College, Jodhpur, India.
Vidya TharuSeth GS Medical College and KEM Hospital, Parel, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVentilator-associated pneumonia (VAP) is a significant nosocomial infection in intensive care units (ICUs). Ventilator bundle (VB) implementation has been shown to decrease the incidence of VAP. This study presents a 1-year quality improvement (QI) project conducted in the ICU of a tertiary care hospital with the goal of increasing VB compliance to greater than 90% and evaluating its impact on VAP incidence and ICU length of stay.

methodsA series of Plan-Do-Study-Act (PDSA) cycles, including educational boot camps, checklist implementation, and simulation-based training, was implemented. Emphasis on standardization and documentation for each VB component further improved compliance. Data were compared using a chi-square test, unpaired t-test, or Mann-Whitney U-Test, as appropriate. A P-value <0.05 was considered statistically significant.

resultsThe initial observed compliance was 40.7%, with a significant difference between knowledge and implementation. The compliance increased to 90% after the second PDSA cycle. In the third PDSA cycle, uniformity and standardization of all components of VAP were ensured. After increasing the VB compliance at greater than 90%, there was a significant decline in the incidence of VAP, from 62.4/1,000 ventilatory days to 25.7/1,000 ventilatory days, with a 2.34 times risk reduction in the VAP rate (P= 0.004).

conclusionsThe study highlights the effectiveness of a structured QI approach in enhancing VB compliance and reducing VAP incidence. There is a need for continued education, protocol standardization, and continuous monitoring to ensure the sustainability of this implementation.

Indexed as

checklistintensive care unitnosocomial infectionquality improvementventilator-associated pneumonia

Identifiers

PMID39558598
PMCPMC11617846

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked