Evidence map›Paper›PMID 39558467›Full record

ArticleJournal of veterinary emergency and critical care (San Antonio, Tex. : 2001)

Evaluation of point-of-care capillary and venous blood glucose concentrations in hospitalized neonatal foals.

Ana Sofia Dias Moreira, Hsin-Yi Weng, Laura D Hostnik, Erin M Beasley, Simon F Peek, Amelia S Munsterman

Abstract readMulticenter Study
In one paragraph

Article in Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Evaluation of point-of-care capillary and venous blood glucose concentrations in hospitalized neonatal foals.Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ana Sofia Dias MoreiraDepartment of Large Animal Clinical Sciences, Michigan State University, East Lansing, Michigan, USA.ORCID https://orcid.org/0000-0002-5460-9765
Hsin-Yi WengDepartment of Comparative Pathobiology, Purdue University, West Lafayette, Indiana, USA.
Laura D HostnikDepartment of Veterinary Clinical Sciences, The Ohio State University, Columbus, Ohio, USA.
Erin M BeasleyDepartment of Large Animal Medicine, University of Georgia, Athens, Georgia, USA.
Simon F PeekDepartment of Medical Sciences, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Amelia S MunstermanDepartment of Large Animal Clinical Sciences, Michigan State University, East Lansing, Michigan, USA.ORCID https://orcid.org/0000-0001-9922-2129

Funding

Companion Animal Fund Research Grant, School of Veterinary Medicine, University of Wisconsin-MadisonSchool of Veterinary Medicine at the University of Wisconsin-Madison
6 · The paper itself

Abstract

objectiveTo compare glucose measurements from capillary and venous blood samples using a point-of-care (POC) glucometer with a standard laboratory (colorimetric, glucose oxidase) assay (LABGLU) in a population of hospitalized, neonatal foals.

designMulticenter, prospective, experimental study, conducted between March 2019 and June 2020.

settingFour university teaching hospitals and 1 private referral hospital. ANIMALS: Fifty-four hospitalized neonatal (≤30 days of age) foals.

interventionsSimultaneous capillary (muzzle, POCMUZ) and venous (jugular, POCJUG) blood samples were obtained to determine POC glucose concentrations. Venous samples were also analyzed by LABGLU. Each foal was sampled at the time of enrollment or admission to the hospital and at 1 subsequent point during hospitalization. Indirect mean arterial pressure and hematocrit were concurrently recorded. MEASUREMENTS AND MAIN

resultsBland-Altman analysis showed a mean bias (95% limits of agreement) of -28.0 (-88.6 to 32.6) mg/dL for comparison of POCJUG with LABGLU, -8.2 (-94.3 to 78.0) mg/dL for POCMUZ and LABGLU, and 18.8 (-44.4 to 82.0) mg/dL for POCMUZ and POCJUG. A total of 63.5% of the POCJUG and 45.2% of the POCMUZ samples exceeded the reference value by ±15 mg/dL (for LABGLU samples <75 mg/dL) or ±15% (for LABGLU samples ≥75mg/dL). Concordance correlation coefficient (95% confidence interval [CI]) indicated a fair agreement between POCJUG and LABGLU (0.75, 95% CI: 0.66-0.82) and between POCMUZ and LABGLU (0.71, 95% CI: 0.58-0.80). Fifty percent (14/28) of hypoglycemic foals on the reference method were incorrectly classified as euglycemic by POCJUG, and 5 of 28 were incorrectly classified by POCMUZ.

conclusionsIn the sampled population, the chosen POC glucometer lacked agreement with the standard laboratory measurement. Limits of agreement were wide for both POCJUG and POCMUZ. Inaccuracies in POC results could impact decision-making in the clinical management of glycemic control in hospitalized neonatal foals and, importantly, increase the risk of hypoglycemic events being underdiagnosed in critical patients.

Indexed as

Animals, NewbornBlood GlucosePoint-of-Care SystemsAnimalsCapillariesFemaleHorsesHospitalizationMaleProspective StudiesBlood Glucosecapillarycritical carefoalglucoseneonatalpoint‐of‐care

Identifiers

PMID39558467
PMCPMC11650952

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.