Evidence map›Paper›PMID 39558392›Full record

ArticleJournal of orthopaedic surgery and research2024

Accuracy of intertrochanteric osteotomy for patients with slipped capital femoral epiphysis operated with 3D printed patient-specific guides.

M van den Boorn, J G G Dobbe, V Lagerburg, M M E H Witbreuk, G J Streekstra

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

M van den Boorn *3D Lab of Department of computerization, automation and medical technology (iMED), OLVG, Amsterdam, The Netherlands. m.vandenboorn@olvg.nl.
J G G Dobbe *Biomedical Engineering and Physics Amsterdam, UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands.
V LagerburgMedical Physics, OLVG, Amsterdam, The Netherlands.
M M E H WitbreukOrthopedic Surgery, OLVG Hospital, Amsterdam, The Netherlands.
G J StreekstraBiomedical Engineering and Physics Amsterdam, UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSlipped Capital Femoral Epiphysis (SCFE), is one of the most common hip disorders in adolescents, and is treated surgically by performing an Imhäuser osteotomy. The use of 3D printed guides has shown promise in improving the accuracy of the osteotomy. However, misplacement of the guide may limit the improvement. Therefore, the aim of this study was to investigate, postoperatively, the degree of malalignment of 3D printed guides compared to the 3D planning.

methodsPatients who underwent surgery between April 2018 and October 2022 and underwent postoperative CT were included in this study. The preoperative CT was used for 3D planning of surgical treatment using 3D printed patient-specific guides and plates. The positioning error of the femoral head and of the patient-specific guide and plate was quantified by analysing the postoperative CT scans using custom software.

resultsFive SCFE patients were included in the study. Femoral head malalignment improved from 16 to 40 mm preoperatively to 11-17 mm postoperatively. Rotational malalignment improved from 29-63⁰ preoperatively to 15-31⁰ postoperatively. Residual error was mostly attributed to plate malposition, with residual translation in the range of 3-13 mm and rotation of 8-28⁰.

conclusionAlthough the postoperative position improved after surgery with 3D printed surgical guides and plates, there was a residual deviation from the planned position persisted. Further research is recommended to improve the design, accuracy of guide placement and surgery in this anatomically challenging region.

Indexed as

OsteotomyPrinting, Three-DimensionalSlipped Capital Femoral EpiphysesTomography, X-Ray ComputedAdolescentChildFemaleFemur HeadHumansMale3D planning3D printed surgical guideImhäuser osteotomySlipped capital femoral epiphysis, Patient-specific, position accuracy.

Identifiers

PMID39558392
PMCPMC11575171

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.