A radiation therapy platform to enable upright cone beam computed tomography and future upright treatment on existing photon therapy machines.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Ultra-low field magnetic resonance breast imaging in prone and seated positions for radiation therapy.Physics and imaging in radiation oncology · 2025Article
- A radiation therapy platform to enable upright cone beam computed tomography and future upright treatment on existing photon therapy machines.Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
Abstract
backgroundThe conventional lying down position for radiation therapy can be challenging for patients due to pain, swallowing or breathing issues. To provide an alternative upright treatment position for these patients, we have developed a portable rotating radiation therapy platform which integrates with conventional photon treatment machines. The device enables cone-beam computed tomography (CBCT) imaging of patients in an upright position, and the future delivery of therapeutic radiation. PURPOSE: To design, manufacture, and test a device for upright radiation therapy. A collaborative partnership between physicists, engineers, radiation therapists, radiation oncologists, implementation researchers and consumers was established, to create a device that meets both the clinical and technical requirements of upright radiation therapy. The device is central to a clinical trial (ACTRN12623000498695) which will evaluate upright image quality in the context of future image guided radiation therapy for patients with lung cancer or head and neck cancer.
methodsThe weight and physical constraints of the device were assessed with respect to the American civilian population. The final design was evaluated with a series of tests to characterize the angular accuracy of the platform rotation and the reproducibility of the platform setup position in a radiation treatment room. To acquire an upright CBCT, the platform movement system was synchronized to the kilo-voltage fluoroscopic imaging on an existing treatment machine. The accuracy of the synchronization was evaluated by assessing the positional reproducibility of upright CBCT imaging of a chest phantom.
resultsThe platform has a weight limit of up to 125 kg which is suitable for approximately 90% of males and 95% of females. The platform has physical constraints that accommodate approximately 95.6% of males and 99.6% of females: a maximum seated height of 97.5 cm, a maximum hip breadth of 63.0 cm, and maximum elbow to knuckle length of 46.5 cm. The angular accuracy of the motion system is within ±0.15° over a full rotation, which is within the guidelines for machine movement accuracy in radiation therapy (1 mm/1°). The platform is a portable device and can be reproducibly positioned in a radiation therapy treatment room with a translational range within ±0.04 mm and a rotational range within ±0.025°. The CBCT imaging can reproducibly detect the position of a chest phantom with a translational uncertainty of ±0.07 mm and a rotational uncertainly of ±0.22°, when imaging is acquired following a strict procedure.
conclusionThe upright radiation therapy platform is suitable for the evaluation of CBCT imaging in the context of image guided radiation therapy. The platform will allow the investigation of open questions in upright radiation therapy in the areas of patient experience, positional stability, anatomical changes, and treatment delivery. Improvements to the materials in the radiation beam line, synchronization with the existing treatment machine, and increasing the device weight limit are suggested prior to delivery of future upright treatments.