Evidence map›Paper›PMID 39556561›Full record

ArticlePloS one2024

Influence of the use of an adhesive connection on the joint strength of modular hip endoprostheses.

Ann-Kathrin Einfeldt, Beate Legutko, Philipp-Cornelius Pott, Benjamin Bergmann, Berend Denkena, Christof Hurschler, Bastian Welke

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ann-Kathrin EinfeldtLaboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery - Annastift DIAKOVERE, Hannover Medical School, Hannover, Germany.
Beate LegutkoInstitute of Production Engineering and Machine Tools, Leibniz University Hannover, Garbsen, Germany.
Philipp-Cornelius PottDepartment of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.ORCID 0000-0003-1217-377X
Benjamin BergmannInstitute of Production Engineering and Machine Tools, Leibniz University Hannover, Garbsen, Germany.
Berend DenkenaInstitute of Production Engineering and Machine Tools, Leibniz University Hannover, Garbsen, Germany.
Christof HurschlerLaboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery - Annastift DIAKOVERE, Hannover Medical School, Hannover, Germany.
Bastian WelkeLaboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery - Annastift DIAKOVERE, Hannover Medical School, Hannover, Germany.ORCID 0000-0003-2526-8129

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionModular hip implants enables a more precise adaptation of the prosthesis to the patient's anatomy. However, they also carry the risk of increased revision rates due to micromotion at the taper junction. In order to minimize this risk, one potential solution is to establish an adhesive bond between the metal taper junctions. Load-stable bonding techniques, already successfully employed in dentistry for connecting materials such as metals and ceramics or different alloys, offer a promising approach. Nevertheless, the bond strength of tapered adhesive bonds in modular hip implants has not been investigated to date. MATERIALS AND

methodsTwenty-eight tapered junctions, consisting of a taper (female taper) and a trunnion (male taper) were turned using TiAl6V4 ELI (n = 16) and CoCr28Mo6 (n = 12). The process parameters cutting speed (vc = 50 m/min or 100 m/min) and feed (f = 0.1 mm, 0.05 mm or 0.2 mm) were varied for the trunnions. For each set of process parameters, one trunnion and one taper were additionally subjected to sandblasting. To investigate the effect of geometry, angular mismatch in the samples were measured. The taper pairs were bonded with a biocompatible adhesive, and push-out tests were subsequently performed.

resultsThe push-out forces generated from the taper connections where both tapers were sandblasted showed a mean push-out force of 5.70 kN. For the samples with only the trunnion sandblasted, the mean force was 0.58 kN, while for the samples with only taper sandblasted the mean push-out force was 1.32 kN. When neither of the tapers was sandblasted the mean push-out force was 0.91 kN. No significant effect of the process parameters on the push-out force was observed. Only the reduced valley depth Svk showed a slight correlation for the CoCr28Mo6 samples (R2 = 0.54). The taper pairs with taper mismatch (between trunnion and taper) greater than |0.1°| did not show lower push-out forces than the specimens with lower taper mismatch.

conclusionsSandblasted and adhesive-bonded tapered connections represent a viable suitable alternative for modular hip implant connections. Slight differences in taper geometry do not result in reduced push-out forces and are compensated by the adhesive. In mechanically joined tapers these differences can lead to higher wear rates. Further investigation under realistic test conditions is necessary to assess long-term suitability.

Indexed as

Hip ProsthesisProsthesis DesignAdhesivesAlloysArthroplasty, Replacement, HipHumansMaterials TestingAdhesivesAlloys

Identifiers

PMID39556561
PMCPMC11573162

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.