Evidence map›Paper›PMID 39556112›Full record

ArticleJournal of veterinary emergency and critical care (San Antonio, Tex. : 2001)

The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs.

Samantha K Day, Katherine J Nash, Mark J Midwinter, Sarah L Purcell, Wendy A Goodwin

Abstract read
In one paragraph

Article in Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs.Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Samantha K DaySchool of Veterinary Science, The University of Queensland, Gatton, Queensland, Australia.ORCID https://orcid.org/0000-0001-5077-9604
Katherine J NashSchool of Veterinary Science, The University of Queensland, Gatton, Queensland, Australia.
Mark J MidwinterSchool of Biomedical Sciences, The University of Queensland, Gatton, Queensland, Australia.
Sarah L PurcellSchool of Veterinary Science, The University of Queensland, Gatton, Queensland, Australia.ORCID https://orcid.org/0000-0002-2228-8610
Wendy A GoodwinSchool of Veterinary Science, The University of Queensland, Gatton, Queensland, Australia.

Funding

John and Mary TrustStone Memorial Fund Kibble Grant
6 · The paper itself

Abstract

objectiveTo establish reference intervals using a new point-of-care thromboelastometry device in dogs for the extrinsically activated test (EX-test), intrinsically activated test (IN-test), fibrin polymerization test (FIB-test), ecarin test (ECA-test), and tissue plasminogen activator test (TPA-test) and to investigate the effects of storage time on the results.

designProspective clinical study in 2022.

settingUniversity teaching hospital. ANIMALS: Forty-eight healthy privately or university-owned dogs were prospectively enrolled and included on the basis of normal physical examination and normal baseline laboratory results (CBC, biochemistry profile, prothrombin time, and activated partial thromboplastin time [aPTT]).

interventionsAfter a 30-minute storage time, the EX-test, IN-test, FIB-test, ECA-test, and TPA-test were performed on citrated blood samples. To determine the effect of storage time, 11 samples had the EX-test, FIB-test, and IN-test repeated 90 and 150 minutes after sample collection. MEASUREMENTS AND MAIN

resultsTen thromboelastometry parameters were evaluated for each test. Reference intervals were calculated using the robust method for parametric data, and the robust Box-Cox transformed or nonparametric methods were used for nonparametric data. Increasing storage time resulted in more hypocoagulable tracings. A correlation was found between the IN-test and aPTT (r = 0.62, P < 0.0001). Other weak to moderate correlations were seen between thromboelastometry parameters and platelet count and hematocrit. CONCLUSIONS AND CLINICAL IMPORTANCE: The development of reference intervals for the thromboelastometry device allows for the clinical use of this technology. Analyzing samples after a prolonged storage time of more than 30 minutes may result in erroneous results. Results may also be affected by an abnormal hematocrit or platelet count.

Indexed as

ThrombelastographyAnimalsDogsFemaleMalePoint-of-Care SystemsProspective StudiesReference Valuescoagulationhemostasispoint of carethromboelastometryviscoelastic testing

Identifiers

PMID39556112
PMCPMC11650927

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.