Evidence map›Paper›PMID 39555434›Full record

ArticleIndian journal of urology : IJU : journal of the Urological Society of India

Creation and evaluation of a three-dimensional-printed synthetic vas deferens for microsurgical training.

Parth Joshi, Tamar Jacobsohn, Andrew Polis, Darshi Shah, Brian Gillette, Richard Schoor

Abstract read
In one paragraph

Article in Indian journal of urology : IJU : journal of the Urological Society of India. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. What's inside.Indian journal of urology : IJU : journal of the Urological Society of India
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Parth JoshiDepartment of Urology, New York University Langone Hospital Long Island, Mineola, NY, USA.
Tamar JacobsohnDepartment of Urology, New York University Langone Hospital Long Island, Mineola, NY, USA.
Andrew PolisDepartment of Urology, New York University Langone Hospital Long Island, Mineola, NY, USA.
Darshi ShahDepartment of Urology, New York University Langone Hospital Long Island, Mineola, NY, USA.
Brian GilletteDepartment of Surgery, New York University Langone Hospital Long Island, Mineola, NY, USA.
Richard SchoorDepartment of Urology, New York University Langone Hospital Long Island, Mineola, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Individuals choose to undergo vasectomy reversal for a variety of reasons, including remarriage or due to the death of a child. To be proficient in this procedure, the surgeons need to be high volume and the trainees require a safe environment to develop their microsurgical skills. To overcome this challenge, we used three-dimensional (3D) printing to create a synthetic model of the vas deferens with properties similar to the human vas deferens. We distributed this model to experienced microsurgeons for evaluation. Methods: The vas deferens model was created using thermoplastic polyurethane filament. The filament was then infused with a foaming agent to allow for temperature-dependent tuning of the material's stiffness. The model's outer diameter was 1 mm and the inner lumen was 0.5 mm. Fellowship-trained male reproductive urologists were recruited from the Society for the Study of Male Reproduction website. They used our model and judged it on several factors by completing a 13-question survey. Results: We received completed evaluations from five microsurgeons. Eighty percent of the surgeons were able to complete a full anastomosis on the model using 9-0 and 10-0 sutures. The majority of the completed anastomoses were performed using the one-layer technique. The average responses for the model's usefulness as a practice tool, a training tool, and overall assessment ranged from 72 to 79 out of 100. Comments for the improvement included the need for a more flexible and softer model. Conclusions: We created a 3D-printed synthetic vas deferens that serves as a valuable training and practice tool.

Identifiers

PMID39555434
PMCPMC11567589

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.