Evidence map›Paper›PMID 39555180›Full record

ArticleRadiology case reports2025

New embolization technique for intracranial vascular disease with the assistance of an Apollo microcatheter.

Jinlu Yu

Abstract readCase Reports
In one paragraph

Article in Radiology case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Jinlu YuDepartment of Neurosurgery, the First Hospital of Jilin University, Changchun 130021, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It is difficult to access small and remote intracranial vascular lesions when using routine coil-delivery microcatheters. A thin Apollo microcatheter can access these vascular lesions. The Apollo microcatheter is intended to reduce the risk of catheter entrapment during the deployment of Onyx due to the detachable tip; furthermore, the Apollo microcatheter with a 3 cm detachable tip has 2 markers. X-ray imaging revealed that the marker on the push lever of the coil matched the proximal marker on the Apollo microcatheter. Therefore, it can replace routine coil-delivery microcatheters to deliver certain coils and then cast Onyx following coiling. The technique has rarely been reported. Patient 1 was a 59-year-old male with a ruptured aneurysm at the branch of posterior cerebral artery. The aneurysm was coiled with a Jasper ®SS-10 coil via an Apollo microcatheter with a 3 cm detachable tip. Then, Onyx-18 was used to obliterate the aneurysm. The patient recovered well after the procedure. Patient 2 was a 51-year-old male with a brain arteriovenous malformation (BAVM). There was a fistulous structure in the nidus. The Apollo microcatheter with a 3 cm detachable tip was used to reach and coil the fistulous structure with a Jasper ®SS-10 coil. Then, Onyx-18 was used to partially embolize the BAVM. The patient recovered well after the procedure. Therefore, the use of an Apollo microcatheter with a 3 cm detachable tip to deliver both coils and Onyx represents a new approach for treating intracranial vascular diseases when routine coil-delivery microcatheters cannot reach the lesions.

Indexed as

AneurysmApollo microcatheterBrain arteriovenous malformationCoilEmbolization

Identifiers

PMID39555180
PMCPMC11564009

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.