Realtime and noninvasive assessment of endotracheal tube displacement using near-infrared and visible cameras.

Tongtong Lu, Pawjai Khampang, Ahmed Beydoun, Anna Berezovsky, Rebecca Rohde, Wenzhou Hong, Joseph E Kerschner, Bing Yu

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tongtong LuJoint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA.ORCID https://orcid.org/0000-0002-7378-9992
Pawjai KhampangDepartment of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA.
Ahmed BeydounDepartment of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA.
Anna BerezovskyDepartment of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA.
Rebecca RohdeDepartment of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA.
Wenzhou HongDepartment of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA.
Joseph E KerschnerDepartment of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA.
Bing YuJoint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA.ORCID https://orcid.org/0000-0001-5943-7969

Funding

Optical confirmation and monitoring of endotracheal tube position in pediatric patientsR21HD105021 · NICHD · MEDICAL COLLEGE OF WISCONSIN · PI KERSCHNER, JOSEPH E, YU, BING · 2021 to 2022
$398k
NICHD NIH HHS R21 HD105021
6 · The paper itself

Abstract

Endotracheal tube (ETT) intubation is a medical procedure routinely used for achieving mechanical ventilation in critically ill patients. Appropriate ETT placement is crucial as undetected tube migration may cause multiple complications or even fatalities. Therefore, prompt detection of unplanned movement of the ETT and immediate action to restore proper placement are essential to ensure patient safety. Despite this necessity, there is not a widely adopted tool for real-time assessment of ETT displacement. We have developed a device, a dual-camera endotracheal tube or DC-ETT, to address this unmet clinical need. This device uses a near-infrared (NIR) LED and a side-firing optical fiber embedded in the side of an ETT to light up the tracheal tissue and a visible and NIR camera module for the displacement detection. The NIR camera tracks the movement of the NIR pattern on the skin, while the visible camera is used to correct the body movements. The efficacy of the DC-ETT was assessed in two piglets with a linear displacement sensor as reference. A mean discrepancy of less than 0.5 mm between the DC-ETT and reference sensor was observed within a displacement range of ±15 mm. The results suggest that the DC-ETT can potentially provide a simple and cost-effective solution for real-time monitoring of ETT displacements in operating rooms, intensive care units, and emergency departments.