A novel technique for trehalose and sucrose determination in therapeutic monoclonal antibodies using a high-performance liquid chromatography-evaporative light scattering detector.
Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Sucrose and trehalose are commonly used excipients in therapeutic monoclonal antibodies that play a pivotal role in ensuring the safety and stability of drugs. Though it is necessary to control the concentrations of these substances during the quality control of their release, there is currently no comprehensive method for simultaneously determining sucrose and trehalose concentrations. Herein, we established a high-performance liquid chromatography-evaporative light scattering detector (HPLC-ELSD) method and validated it in accordance with the International Council for Harmonization Q2 guidelines. This method utilized the Poroshell 120 HILIC-Z chromatographic column and effectively separated sucrose and trehalose with a detection limit of 0.001 mg/mL. The accuracy recovery rate was within a range of 90%-110 %, and the precision relative standard deviations were all less than 5.0 % (n = 6). The method thus demonstrated good repeatability and linearity, making it suitable for determining the sucrose and trehalose concentrations in therapeutic monoclonal antibodies.