Evidence map›Paper›PMID 39552954›Full record

ArticleCureus2024

Establishing Diagnostic Reference Levels for Single-Photon Emission Computed Tomography (SPECT) Imaging: A Preliminary Study in Indian Healthcare Settings.

Ashutosh Pandey, Vandana K Dhingra, Mayank Goswami, Prabhaker Mishra, Pankaj Sharma

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ashutosh PandeyNuclear Medicine, All India Institute of Medical Sciences, Rishikesh, Rishikesh, IND.
Vandana K DhingraNuclear Medicine, All India Institute of Medical Sciences, Rishikesh, Rishikesh, IND.
Mayank GoswamiPhysics, Indian Institute of Technology (IIT) Roorkee, Roorkee, IND.
Prabhaker MishraBiostatistics and Health Informatics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, IND.
Pankaj SharmaRadiology, All India Institute of Medical Sciences, Rishikesh, Rishikesh, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction In nuclear medicine, there is a critical need to balance the control and optimization of radiation doses to ensure patient safety while achieving high-quality diagnostic outcomes. However, diagnostic reference levels (DRLs) for nuclear medicine imaging studies have not been established in India. This study aims to fill this gap by establishing institutional DRLs and assessing radiation dose data specifically for Nuclear Medicine SPECT examinations. Methods This research was a cross-sectional observational study conducted in a single tertiary care setting, involving 1,250 patients. Data on the administered activity for 18 common single photon emission computed tomography (SPECT) procedures were gathered from 2019 to 2021. The 75th percentile (Q3) was established as the baseline for the institutional DRLs. Furthermore, the study conducted comparative analyses with established international DRLs. Results The study proposed institutional DRLs based on 18 SPECT nuclear medicine imaging examinations. The highest Q3 DRLs were identified for 99mTc-sestamibi (1193 MBq), followed by 99mTc-methylene diphosphonate (747 MBq) and 99mTc-ethyl cysteinate dimer (608 MBq). The lowest DRL was recorded for 99mTc gastric emptying imaging (37 MBq). Comparisons with international DRLs indicated close alignment with European Association of Nuclear Medicine Medical Internal Radiation Dose guidelines, while DRLs set by the National Council on Radiation Protection and Measurements (NCRP) were identified as distinct in several key aspects when compared to other established DRLs. Conclusion This research marks a significant step toward standardizing SPECT procedure doses in India, contributing to improved patient safety and care in nuclear medicine. The established DRLs will enhance the optimization of administered activities, ensure adherence to international standards, and improve diagnostic quality while reducing radiation exposure. These institutional DRLs will serve as the foundation for developing a roadmap to establish national DRLs.

Indexed as

diagnostic reference levelinstitutional reference levelnuclear medicineradiation dosesingle photon emission computed tomography

Identifiers

PMID39552954
PMCPMC11568968

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.