Evidence map›Paper›PMID 39550458›Full record

ArticleScientific reports2024

Evaluation of a compact cone beam CT concept with high image fidelity for point-of-care brain imaging.

Uttam Pyakurel, Ryan Sabounchi, Mohamed Eldib, Farhang Bayat, Hien Phan, Cem Altunbas

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Uttam PyakurelDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA. uttam.pyakurel@cuanschutz.edu.
Ryan SabounchiDepartment of Bioengineering, University of Colorado Denver, 12705 East Montview Boulevard, Suite 100, Aurora, CO, 80045, USA.
Mohamed EldibDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA.
Farhang BayatDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA.
Hien PhanDepartment of Mechanical Engineering, University of Colorado Denver College of Engineering, Design and Computing, 1200 Larimer Street Suite 3034, Denver, CO, 80204, USA.
Cem AltunbasDepartment of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA. cem.altunbas@cuanschutz.edu.

Funding

Colorado REACH HubU01HL152405 · NHLBI · UNIVERSITY OF COLORADO DENVER · PI DUKE, RICHARD C · 2019 to 2022
$5.1M
Improving quantitative accuracy and tissue visualization in CBCT guided radiation therapyR01CA245270 · NCI · UNIVERSITY OF COLORADO DENVER · PI ALTUNBAS, CEM · 2020 to 2025
$2.1M
A two-dimensional antiscatter grid for dental cone beam computed tomographyR41DE030039 · NIDCR · M2 TECHNOLOGIES LLC · PI ALTUNBAS, CEM · 2021 to 2021
$197k
Foundation for the National Institutes of Health R01CA245270Foundation for the National Institutes of Health R41DE030039Foundation for the National Institutes of Health U01HL152405NCI NIH HHS R01 CA245270NHLBI NIH HHS U01 HL152405NIDCR NIH HHS R41 DE030039
6 · The paper itself

Abstract

Cone beam computed tomography (CBCT) has potential advantages for developing portable, cost-effective point-of-care CT systems for intracranial imaging, such as early stroke diagnosis, hemorrhage detection, and intraoperative navigation. However, large volume imaging with flat panel detector based CBCT significantly increases the scattered radiation fluence which reduces its image quality and utility. To address these issues, a compact CBCT concept with enhanced image quality was investigated for intracranial imaging. The new system features a novel antiscatter collimator and data correction method to address the challenges in imaging large volumes with CBCT. A benchtop CBCT prototype was constructed. Imaging studies with anthropomorphic phantoms showed that soft tissue visualization, Hounsfield Unit (HU) accuracy, contrast, and spatial resolution increased significantly with the proposed CBCT concept, and they were comparable to the values measured in the gold standard multidetector-row CT (MDCT) images. Contrast-to-noise ratio (CNR) in CBCT images was within 12-31% of the CNR in MDCT images. These findings indicate that a compact CBCT system integrated with effective scatter suppression techniques may have increased utility in the context of brain imaging, and the proposed approach may enable the development of point-of-care CT systems for head imaging based on flat panel detector based CBCT technology.

Indexed as

BrainCone-Beam Computed TomographyPhantoms, ImagingPoint-of-Care SystemsHumansSignal-To-Noise RatioAntiscatter gridCompact CBCTImage quality enhancement in CBCTPoint of care CT systemScatter mitigation

Identifiers

PMID39550458
PMCPMC11569191

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.