In one paragraph

Article in BMC medical education, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Daniel EinsiedelDepartment of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
Stephanie Knapp GiacamanDepartment of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
Anna SeidelDepartment of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany. anna.seidel@uk-erlangen.de.
Lara BergerDepartment of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
Mayte BuchbenderDepartment of Oral and Maxillofacial Surgery, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
Manfred WichmannDepartment of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany.
Ragai Edward MattaDepartment of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander University Erlangen-Nürnberg (FAU), Glueckstrasse 11, 91054, Erlangen, Germany. ragai.matta@uk-erlangen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis in vitro study investigated whether full-guided (FG) or half-guided (HG) implant placement is more suitable for beginners and to what extent the use of the coDiagnostiX (CDX) (10.5, Straumann Group, Basel, Switzerland) implant planning software proves useful in teaching.

methodsTwenty students planned implant positions with CDX which were then placed in a model using printed drill templates in the sense of FG implantation (group 1) and HG implantation (group 2). The implant positions could be compared with those of the reference model, and deviations could be determined. The results were tested for significance using the t-test for independent samples for groups 1 and 2. A total of 32 students subsequently completed a questionnaire about the software. Cronbach's α was also calculated to check the reliability of the questions for the individual subject areas.

resultsIn both groups the greatest deviation occurred along the y-axis in the vestibular direction. It measured 1.390 mm in group 1 and 1.570 mm in group 2. Comparing both groups, there were significant deviations along the y-axis (p = .013), along the z-axis (p = .049), and in the total deviation (p = .031). The questionnaire was evaluated in design, with 95% positive answers. In contrast, the evaluation of the area of time and effort resulted in only 55% positive responses. Overall, experience with the software was rated as positive by 74%.

conclusionsGroup 1 achieved more accurate results, especially along the y-axis in the vestibular direction. In both groups, the implants were placed too deep. The questionnaire indicated a software with high usability and is therefore very suitable for teaching. If clinically feasible, beginners should prefer full-guided implant placement.

Indexed as

CurriculumSoftwareDental Implantation, EndosseousHumansReproducibility of ResultsSurgery, Computer-AssistedSurveys and QuestionnairesDental educationDental implantationDigital dentistryDigital implant planningStudentsSurveys and questionnairesTeaching methods

Identifiers

PMID39548519
PMCPMC11566595

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.