ArticleJournal of the American Society for Mass Spectrometry2024
Strategies for Using Postcolumn Infusion of Standards to Correct for Matrix Effect in LC-MS-Based Quantitative Metabolomics.
Article in Journal of the American Society for Mass Spectrometry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Comparative Pharmacokinetics of Six Bioactive Constituents From Danggui Jixueteng Decoction in Normal and Myelosuppressive Rats.Analytical science advances · 2026Article
- A novel multi-aptamer electrospun nanofibrous membrane for simultaneous selective extraction of monoamine neurotransmitters and determination in biological samples by LC-MS.Analytical and bioanalytical chemistry · 2026Article
- Method development and validation for determination of entinostat in human plasma and its application in breast cancer patients.RSC advances · 2026Article
- Development and Validation of a UPLC-MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies.Drug design, development and therapy · 2026Article
- AI redefine untargeted metabolomics: estimating chemical amounts for a Human Exposome Project.Frontiers in public health · 2026Review
- Article
- Plasma-Free Metanephrine and Normetanephrine Quantification for Clinical Applications Validated by Combining Solid-Phase Extraction and HPLC-MS/MS.Molecules (Basel, Switzerland) · 2025Article
- Standardization via Post Column Infusion-A Novel and Convenient Quantification Approach for LC-MS/MS.Molecules (Basel, Switzerland) · 2024Article
- A Comprehensive Review of Instrumentation and Applications in Post-Column and In-Source Derivatization for LC-MS.Mass spectrometry reviewsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The matrix effect limits the accuracy of quantitation of the otherwise popular metabolomics technique liquid chromatography coupled to mass spectrometry (LC-MS). The gold standard to correct for this phenomenon, whereby compounds coeluting with the analyte of interest cause ionization enhancement or suppression, is to quantify an analyte based on the peak area ratio with an isotopologue added to the sample as an internal standard. However, these stable isotopes are expensive and sometimes unavailable. Here, we describe an alternative approach: matrix effect correction and quantifying analytes using a signal ratio with a postcolumn infused standard (PCIS). Using an LC-MS/MS method for eight endocannabinoids and related metabolites in plasma, we provide strategies to select, optimize, and evaluate PCIS candidates. Based on seven characteristics, the structural endocannabinoid analogue arachidonoyl-2'-fluoroethylamide was selected as a PCIS. Three methods to evaluate the PCIS correction vs no correction showed that PCIS correction improved values for the matrix effect, precision, and dilutional linearity of at least six of the analytes to within acceptable ranges. PCIS correction also resulted in parallelization of calibration curves in plasma and neat solution, for six of eight analytes even with higher accuracy than peak area ratio correction with their stable isotope labeled internal standard, i.e., the gold standard. This enables quantification based on neat solutions, which is a significant step toward absolute quantification. We conclude that PCIS has great, but so far underappreciated, potential in accurate LC-MS quantification.