Evidence map›Paper›PMID 39544571›Full record

ArticleCureus2024

Prosthetic Neck Fracture of a Cementless Titanium Femoral Stem.

Zakhia Michael Malhame, Fouad Lamnaouar, Abdel Massih Abou Chaaya

Abstract readCase Reports
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Zakhia Michael MalhameOrthopedics and Traumatology, Centre Hospitalier Victor Dupouy, Argenteuil, FRA.
Fouad LamnaouarOrthopedics and Traumatology, Centre Hospitalier Victor Dupouy, Argenteuil, FRA.
Abdel Massih Abou ChaayaOrthopedics and Traumatology, Centre Hospitalier Victor Dupouy, Argenteuil, FRA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This case report presents a unique instance of a prosthetic neck fracture in an 81-year-old male with a CERAVER CERAFIT titanium (Ti6Al4V) femoral implant paired with a ceramic-on-ceramic total hip replacement. No fractures of the neck of a titanium femoral stem coated with hydroxy-apatite have been reported in the literature for this type of implant. The patient experienced a sudden, non-traumatic fracture, many years after his primary surgery. The report discusses the clinical presentation, diagnostic findings, known risk factors for femoral neck implant fractures, surgical management, and the outcome.

Indexed as

cementless total hip arthroplastyfemorotomyprosthetic neck fracturestress-fracturetitanium implant

Identifiers

PMID39544571
PMCPMC11561529

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.