Evidence map›Paper›PMID 39544300›Full record

ArticleFrontiers in oncology2024

A multi-institutional trial evaluating the use of an integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.

Dante P I Capaldi, Lawrie B Skinner, Daniel W Pinkham, Sergei Zavgorodni, Olga Stafford, Maryam Shirmohammad, Jason E Matney, Piotr Dubrowski, Paul De Jean, Elliot M Grafil and 1 more

Abstract read
In one paragraph

Article in Frontiers in oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Dante P I CapaldiDepartment of Radiation Oncology, University of California, San Francisco (UCSF) Comprehensive Cancer Centre, San Francisco, CA, United States.
Lawrie B SkinnerDepartment of Radiation Oncology, School of Medicine, Stanford University, Stanford, CA, United States.
Daniel W PinkhamDepartment of Therapeutic Radiology, Yale School of Medicine, New Haven, CT, United States.
Sergei ZavgorodniBritish Columbia Cancer Agency, Vancouver Island Centre, Victoria, BC, Canada.
Olga StaffordDepartment of Radiation Oncology, Alta Bates Summit Medical Center SutterHealth, Berkeley, CA, United States.
Maryam ShirmohammadDepartment of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States.
Jason E MatneyDepartment of Radiation Oncology, University of California, Davis School of Medicine, Sacramento, CA, United States.
Piotr DubrowskiDepartment of Radiation Oncology, School of Medicine, Stanford University, Stanford, CA, United States.
Paul De JeanLuca Medical Systems, Palo Alto, CA, United States.
Elliot M GrafilLuca Medical Systems, Palo Alto, CA, United States.
Amy S YuDepartment of Radiation Oncology, School of Medicine, Stanford University, Stanford, CA, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Brain radiosurgery treatments require multiple quality-assurance (QA) procedures to ensure accurate and precise treatment delivery of ablative doses. As single-isocenter multitarget radiosurgery treatments become more popular for treating patients with multiple brain metastases, quantifying off-axis accuracy of linear accelerators is crucial. In this study, we developed a novel brain radiosurgery integrated phantom and validated this phantom at multiple institutions to enable radiosurgery QA with a single phantom to facilitate implementation of a frameless single-isocenter, multitarget radiosurgery program. The phantom combines multiple independent verification system tests including the Winston-Lutz test, off-axis accuracy evaluation (i.e., off-axis Winston-Lutz), as well as dosimetric measurements utilizing both point dose and film measurement. Methods and materials: A novel 3D-printed phantom, coined Results: Dose verification performed using the OneIso phantom across the different centers were all within on average 3% agreement, for both film and point-dose measurements. OneIso identified a reduction in spatial accuracy further away from isocenter for all eight radiosurgery machines. Differences increased as distance from isocenter increased, exceeding recommended radiosurgery accuracy tolerances (<1mm) at different distances for each machine (2-7cm), indicating that the tolerance is machine-dependent. Conclusion: OneIso provides a streamlined, single-setup workflow for single-isocenter multitarget frameless linac-based radiosurgery QA that can be easily translated to multiple institutions. Additionally, quantifying off-axis spatial discrepancies allows for determination of the maximum distance between targets and iso that meet single-isocenter multitarget radiosurgery program recommendations.

Indexed as

3D printingframeless brain radiosurgery treatmentoff-axis Winston-Lutzquality assurancesingle isocenter multi-targetstereotactic radiosurgery

Identifiers

PMID39544300
PMCPMC11560902

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked