ArticleEJNMMI physics2024

Optimization and application of renal depth measurement method in the cadmium-zinc-telluride‑based SPECT/CT renal dynamic imaging.

Hongyuan Zheng, Xiangxiang Li, Shen Wang, Shasha Hou, Chunling Shi, Xue Li, Qiang Jia, Wei Zheng

Abstract read
In one paragraph

Article in EJNMMI physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hongyuan Zheng *Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Xiangxiang Li *Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Shen Wang *Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Shasha HouDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Chunling ShiDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Xue LiDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Qiang JiaDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
Wei ZhengDepartment of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China. zhengw@tmu.edu.cn.ORCID http://orcid.org/0000-0003-1206-9243

Funding

National Natural Science Foundation of China 81601523National Natural Science Foundation of China 82202205
6 · The paper itself

Abstract

purposeThis study aims to evaluate the accuracy of four kidney depth measurement methods-nuclear medicine tomography, nuclear medicine lateral scanning, ultrasound, and Tonnesen's formula-based estimation-using CT measurements as the reference standard. Additionally, it investigates the feasibility of utilizing nuclear medicine tomography and lateral scanning for measuring kidney depth in

methodsHollow kidney phantoms mimicking the shape and volume of adult kidneys were 3D printed and filled with

resultsUsing kidney phantoms, nuclear medicine tomography images were processed with a Butterworth filter (cutoff frequency = 0.6), and renal outlines in lateral images was manually delineated. In the clinical validation phase, correlation coefficients indicated strong associations between renal depths measured by nuclear medicine tomography (left kidney: R = 0.885, P < 0.05; right kidney: R = 0.927, P < 0.05) and lateral scanning (left kidney: R = 0.933, P < 0.05; right kidney: R = 0.956, P < 0.05) compared to CT measurements. The difference in kidney depth between nuclear medicine tomography and CT measurements were the smallest and statistically significant (left kidney: 0.69 ± 0.51; right kidney: 0.58 ± 0.41, P < 0.05).

conclusionUsing ordered subset expectation maximization (OSEM) in conjunction with a Butterworth filter (fc = 0.6) as the post-processing method, nuclear medicine tomography enables more accurate renal depth measurements without increasing the radiation dose to patients.

Indexed as

3D printingCZT SPECT/CTFilterImage post-processingPhantom imagingRenal depthRenal dynamic imaging

Identifiers

PMID39542940
PMCPMC11564595

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.