Evidence map›Paper›PMID 39541010›Full record

ArticleRadiological physics and technology2025

Evaluation of dose distributions and respiratory motion tolerance for layer-stacking conformal carbon-ion radiotherapy.

Yuki Hasebe, Mutsumi Tashiro, Hiroshi Sakurai

Abstract readEvaluation Study
In one paragraph

Article in Radiological physics and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuki HasebeGraduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma, 376-8515, Japan.
Mutsumi TashiroGunma University Heavy Ion Medical Center, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511, Japan. tashiro@gunma-u.ac.jp.ORCID http://orcid.org/0000-0003-3253-0527
Hiroshi SakuraiGraduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma, 376-8515, Japan.ORCID http://orcid.org/0000-0002-8132-8723

Funding

Japan Science and Technology Agency JPMJSP2146
6 · The paper itself

Abstract

While layer-stacking irradiation provides a conformal dose distribution, it is vulnerable to respiratory motion. Considering that the motion tolerance has not yet been demonstrated, this study aimed to determine the tolerance level for the amount of target motion. Dose distributions considering motion were simulated for a numerical water phantom using in-house software. Comparisons with measured and simulated physical dose distributions confirmed the validity of the simulation, with gamma analysis showing almost 90% or greater agreement under all conditions with a criterion of 3%/3 mm. The variation in physical dose from static conditions followed a similar trend. Based on the evaluation of the simulated clinical dose uniformity, motion tolerance was derived. The acceptable motion amounts in the lateral direction were 11 mm in respiratory-ungated condition and at least 20 mm with 30% lateral gating at 4 Gy (RBE). In the longitudinal (beam upstream) direction, the acceptable target motion amounts were 3 mm without gating and 6 mm with gating. These results employed worst-case scenarios considering multiple respiratory cycles. In both lateral and longitudinal directions, the motion amounts of 3 mm for non-gating and 5 mm for gating were acceptable. The acceptable target motion amounts improved by 1-9 mm with gating and increased prescribed doses. The dose uniformity and motion tolerance under multiple conditions, although based on a simple system, may be useful for treatment involving target motion in layer-stacking irradiation.

Indexed as

Heavy Ion RadiotherapyRadiation DosageRadiotherapy, ConformalRespirationHumansMovementPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedCarbon-ion radiotherapyLayer-stacking irradiationMotion tolerancePassive beamRespiratory motion

Identifiers

PMID39541010
PMCPMC11876241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.