Evidence map›Paper›PMID 39540016›Full record

ReviewInternational journal of cardiology. Heart & vasculature2024

Hemodynamic and clinical outcomes with balloon-expandable valves versus self-expanding valves in patients with small aortic annulus undergoing transcatheter aortic valve replacement: A

Mushood Ahmed, Areeba Ahsan, Shehroze Tabassum, Irra Tariq, Eeshal Zulfiqar, Mahnoor Farooq Raja, Asma Mahmood, Raheel Ahmed, Farhan Shahid, Syed Khurram M Gardezi and 3 more

Abstract readReview
In one paragraph

Review in International journal of cardiology. Heart & vasculature, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Recent highlights from theInternational journal of cardiology. Heart & vasculature · 2025
    Article
  2. Transcatheter aortic valve implantation: latest evidence, gaps in knowledge, and future directions.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Mushood AhmedRawalpindi Medical University, Rawalpindi, Pakistan.
Areeba AhsanFoundation University Medical College, Islamabad, Pakistan.
Shehroze TabassumKing Edward Medical College, Lahore, Pakistan.
Irra TariqUnited Medical and Dental College, Karachi, Pakistan.
Eeshal ZulfiqarDow University of Health Sciences, Karachi, Pakistan.
Mahnoor Farooq RajaAllama Iqbal Medical College, Lahore Pakistan.
Asma MahmoodAllama Iqbal Medical College, Lahore Pakistan.
Raheel AhmedDepartment of Cardiology, Royal Brompton Hospital, London, UK.
Farhan ShahidDepartment of Interventional Cardiology, Queen Elizabeth Hospital, Birmingham, UK.
Syed Khurram M GardeziCollege of Medicine and Health Sciences, Khalifa University, Abu Dhabi, United Arab Emirates.
Mahboob AlamDepartment of Interventional Cardiology, Baylor College of Medicine, Houston, TX, USA.
Rodrigo BagurDivision of Cardiology, London Health Sciences Centre, Western University, London, Ontario, Canada.
Mamas A MamasKeele Cardiovascular Research Group, Centre for Prognosis Research, Keele University, Stoke-On-Trent, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transcatheter aortic valve replacement (TAVR) is considered more effective than surgical aortic valve implantation for patients with a small aortic annulus (SAA), however, the comparative efficacy of different transcatheter heart valves (THVs) remains uncertain. A literature search was performed across databases from their inception until June 2024 to identify eligible randomized controlled trials (RCTs) and propensity-score matched (PSM) studies. Clinical outcomes were evaluated using a random-effects model to pool risk ratios (RRs) with 95 % confidence intervals (CIs). The analysis included 10 studies with 2,960 patients. BEVs were associated with a significantly smaller indexed effective orifice area (MD: -0.18, 95 % CI: -0.27 to -0.10), and a higher transvalvular mean pressure gradient (MD: 5.07, 95 % CI 3.43 to 6.71) than SEVs. The risk for prosthesis-patient mismatch (PPM) (RR = 1.89, 95 % CI: 1.42 to 2.51) and severe PPM (RR = 2.80, 95 % CI: 1.96 to 4.0) was significantly higher for patients receiving BEVs than those receiving SEVs. Although nonsignificant differences were observed between BEVs and SEVs regarding 30-day and 1-year all-cause mortality, 30-day stroke rates, vascular complication, paravalvular leak, and permanent pacemaker implantation (p > 0.05), patients receiving BEVs were associated with a significantly increased risk of 1-year cardiovascular mortality (RR = 1.61, 95 % CI: 1.05 to 2.47) compared to those receiving SEVs. In patients with SAA, BEVs demonstrated worse hemodynamic performance as determined by the higher risk of moderate and severe PPM compared to SEVs. Moreover, the use of BEVs was associated with a higher risk of 1-year cardiovascular mortality.

Indexed as

Balloon-expandable valvesSelf-expanding valvesTranscatheter aortic valve replacement

Identifiers

PMID39540016
PMCPMC11558639

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.