Evidence map›Paper›PMID 39537709›Full record

ArticleScientific reports2024

Enhancing load frequency control and automatic voltage regulation in Interconnected power systems using the Walrus optimization algorithm.

Ark Dev, Kunalkumar Bhatt, Bappa Mondal, Vineet Kumar, Vineet Kumar, Mohit Bajaj, Milkias Berhanu Tuka

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ark DevDepartment of Electrical Engineering, Parul Institute of Engineering and Technology, Parul University, Vadodara, Gujarat, India.
Kunalkumar BhattDepartment of Electrical Engineering, Parul Institute of Engineering and Technology, Parul University, Vadodara, Gujarat, India.
Bappa MondalDepartment of Mechanical Engineering, GMR Institute of Technology, Rajam, Vizianagaram, Andhra Pradesh, India.
Vineet KumarDepartment of Electrical Engineering, Parul Institute of Engineering and Technology, Parul University, Vadodara, Gujarat, India.
Vineet KumarDepartment of Electrical and Electronics Engineering, Madanapalle Institute of Technology and Science, Madanapalle, Andhra Pradesh, India.
Mohit BajajDepartment of Electrical Engineering, Graphic Era (Deemed to be University), Dehradun, 248002, India. mb.czechia@gmail.com.
Milkias Berhanu TukaHourani Center for Applied Scientific Research, Al-Ahliyya Amman University, Amman, Jordan. milkias.berhanu@aastu.edu.et.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper introduces the Walrus Optimization Algorithm (WaOA) to address load frequency control and automatic voltage regulation in a two-area interconnected power systems. The load frequency control and automatic voltage regulation are critical for maintaining power quality by ensuring stable frequency and voltage levels. The parameters of fractional order Proportional-Integral-Derivative (FO-PID) controller are optimized using WaOA, inspired by the social and foraging behaviors of walruses, which inhabit the arctic and sub-arctic regions. The proposed method demonstrates faster convergence in frequency and voltage regulation and improved tie-line power stabilization compared to recent optimization algorithms such as salp swarm, whale optimization, crayfish optimization, secretary bird optimization, hippopotamus optimization, brown bear optimization, teaching learning optimization, artificial gorilla troop optimization, and wild horse optimization. MATLAB simulations show that the WaOA-tuned FO-PID controller improves frequency regulation by approximately 25%, and exhibits a considerable faster settling time. Bode plot analyses confirm the stability with gain margins of 5.83 dB and 9.61 dB, and phase margins of 10.8 degrees and 28.6 degrees for the two areas respectively. The system modeling and validation in MATLAB showcases the superior performance and reliability of the WaOA-tuned FO-PID controller in enhancing power system stability and quality under step, random step load disturbance, with nonlinearities like GDC and GDB, and system parameter variations.

Indexed as

Automatic voltage regulationFO-PID controllerFrequency regulationLoad frequency controlMetaheuristic optimizationPower system stabilityVoltage stabilityWalrus optimization algorithm

Identifiers

PMID39537709
PMCPMC11560927

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.