Evidence map›Paper›PMID 39536183›Full record

ArticleActa cirurgica brasileira2024

Development and validation of the thyroidectomy training box: cervical simulator for training endoscopic transoral thyroidectomy.

Valdenor Neves Feitosa, Taís Vasconcelos Cidrão, Ingrid Arruda Castro, Klayton Coelho de Souza Júnior, Sarah Rodrigues Chaves Martins, Francisco Everton Pereira da Silva, Luiz Gonzaga Moura Junior

Abstract readValidation Study
In one paragraph

Article in Acta cirurgica brasileira, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Valdenor Neves FeitosaCentro Universitário Christus - Fortaleza (CE) - Brazil.ORCID http://orcid.org/0009-0009-0625-7185
Taís Vasconcelos CidrãoCentro Universitário Christus - Fortaleza (CE) - Brazil.ORCID http://orcid.org/0000-0001-5144-0602
Ingrid Arruda CastroCentro Universitário Christus - Fortaleza (CE) - Brazil.ORCID http://orcid.org/0000-0003-2275-4690
Klayton Coelho de Souza JúniorORCID http://orcid.org/0000-0003-4468-9260
Sarah Rodrigues Chaves MartinsCentro Universitário Christus - Fortaleza (CE) - Brazil.ORCID http://orcid.org/0009-0009-4638-025X
Francisco Everton Pereira da SilvaCentro Universitário Christus - Fortaleza (CE) - Brazil.ORCID http://orcid.org/0009-0008-3710-6585
Luiz Gonzaga Moura JuniorCentro Universitário Christus - Fortaleza (CE) - Brazil.ORCID http://orcid.org/0000-0003-0092-648X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo develop and validate a trans oral endoscopic thyroidectomy vestibular approach (TOETVA) simulator.

methodsThe first phase of the project consisted of designing and developing a transoral thyroid surgery simulator based on real surgeries. The product has the oral cavity for attaching the three trocars and the cervical part containing the thyroid and adjacent structures. In the second phase, the simulator was validated by specialists who performed an endoscopic thyroidectomy procedure. They all filled a questionnaire about the simulator and the simulation based on the Likert scale.

resultsThe simulator consists of a console similar to a human bust and a high-resolution camera system connected to a 22-inch monitor. The simulator had excellent results in the visual evaluation (face validity), with 100% of responses between good and excellent for the following characteristics: synthetic structures, design, visibility of the surgery field, resistance, resilience, fulcrum effect, ergonomics, surgical material, and practicality. The last three were rated higher, with more votes for excellent. For content validity, the items that received the best ratings were, precisely, the steps relating to the surgical procedure: opening the intermuscular midline, isthmotomy, and thyroidectomy.

conclusionsThe thyroidectomy training box showed great ability to simulate a TOETVA, with satisfactory evaluations concerning its visual and content validation.

Indexed as

Simulation TrainingThyroidectomyClinical CompetenceComputer SimulationEquipment DesignHumansNatural Orifice Endoscopic SurgeryReproducibility of ResultsSurveys and Questionnaires

Identifiers

PMID39536183
PMCPMC11548132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.