ArticleArthroplasty today2024

Is Wear Still a Concern in Total Knee Arthroplasty With Contemporary Conventional and Highly Crosslinked Polyethylene Tibial Inserts in the mid- to Long-Term?

Devin P Asher, Jennifer L Wright, Deborah J Hall, Hannah J Lundberg, Douglas W Van Citters, Joshua J Jacobs, Brett R Levine, Robin Pourzal

Abstract read
In one paragraph

Article in Arthroplasty today, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Devin P AsherDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Jennifer L WrightDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Deborah J HallDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Hannah J LundbergDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Douglas W Van CittersThayer School of Engineering, Dartmouth College, Hanover, NH, USA.
Joshua J JacobsDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Brett R LevineDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Robin PourzalDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Modern literature has brought into question if wear of tibial inserts made from conventional or highly crosslinked polyethylene (HXL PE) is still a factor limiting longevity of total knee arthroplasty (TKA) in the mid- to long-term. It is the objective of this study to determine: 1) most common causes of mid- to long-term TKA failure, 2) the prevalence of delamination, and 3) the medial/lateral linear wear rates of conventional and HXL PE tibial inserts retrieved in the mid- to long-term. Methods: A tibial insert retrieval cohort of 107 inserts (79 conventional, 28 HXL PE) with a minimum time in situ of 6.5 years (mean 11.7 ± 4) was studied. Failure causes were determined from chart-review, delamination presence was assessed microscopically, and medial/lateral linear wear was determined by minimal thickness changes measured with a dial-indicator. Results: The most common mid-to long-term etiologies for failure were instability (44.9%), PE wear 15%), aseptic loosening (14%), and infection (13.1%). Delamination occurred in 70% of inserts (72.1% conventional, 64.3% HXLPE). Gross material loss due to delamination appeared to be the underlying reason for at least 33.3% of cases exhibiting instability. Of the cases removed for infection, 75% exhibited no histopathological hallmarks of acute infection. The medial/lateral wear rates were 0.054/0.051 (conventional) and 0.014/0.011 (HXL) mm/y, respectively. Conclusions: Polyethylene wear still appears to be a major primary and secondary cause for TKA revision in the mid- to long-term. Wear may manifest as destabilizing delamination or as continuous release of fine wear particles potentially resulting in inflammatory responses and subsequent failure.

Indexed as

DelaminationHighly crosslinkedPolyethyleneTibial insertsTotal knee arthroplastyWear

Identifiers

PMID39534215
PMCPMC11555350

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.