ArticleScientific reports2024
Experimental and theoretical investigation of cationic-based fluorescent-tagged polyacrylate copolymers for improving oil recovery.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Thermally stable gel particles with optimized performance for high-temperature conformance control.BMC chemistry · 2025Article
- Review
- Experimental and numerical simulation studies of the zwitterionic polymers for enhanced oil recovery.Scientific reports · 2025Article
- A Novel Polyacrylamide Film-Forming Agent for Maintaining Wellbore Stability.Molecules (Basel, Switzerland) · 2025Article
- Exploring synergistic effects of graphene oxide and hydrolyzed polyacrylamide on rheology and thermal stability relevant to enhanced oil recovery.Scientific reports · 2025Article
- Machine learning models for estimating the overall oil recovery of waterflooding operations in heterogenous reservoirs.Scientific reports · 2025Article
- Elevated temperature and pressure performance of water based drilling mud with green synthesized zinc oxide nanoparticles and biodegradable polymer.Scientific reports · 2025Article
- Interfacial tension reduction and viscosity control by chemically grafted polymeric surfactant for enhanced oil recovery.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The growing need for energy and the depletion of oil wells necessitate advanced Enhanced Oil Recovery (EOR) techniques, particularly water and polymer flooding, which play a crucial role in augmenting hydrocarbon recovery rates. However, water flooding in high-permeability layers often leads to water breakthroughs, reduced sweep efficiency, and the formation of preferential channels, posing significant challenges to oil recovery and reservoir management. Conformance control treatments, including the use of polymer microspheres, offer a promising solution by sealing high-permeability zones and enhancing sweep efficiency. This study focuses on the application of fluorescent polymer microspheres based on polyacrylamide, which is extensively employed in the oil sector as an oil displacement agent. Fluorescent polymers called Poly 400, Poly 200, and Poly 600, incorporating cationic methacrylamide monomers, were synthesized through copolymerization to create amphiphilic polymers with enhanced stability and functionality. These fluorescent polymers were evaluated through flooding tests using a quarter-five-spot model of transparent quartz glass under UV light, allowing for instantaneous measurement and observation of fluorescence intensity. At reservoir conditions, the oil displacement experiments confirm that the incremental oil after water flooding by Poly 400, Poly 200, and Poly 600, is 13.1%, 9.1%, and 6.1% of OOIP respectively. The findings showed that fluorescent polymer microspheres could efficiently target high-permeability layers, adapt to varying pore throat sizes, and improve the plugging rate of high-permeability channels, thereby optimizing oil recovery. A subsequent simulation study using the CMG simulator provided further insights into the efficacy of these fluorescent polymers as EOR agents, revealing their potential to enhance sweep efficiency and enhance oil recovery. Simulation results showed that oil saturation decreased from 68% (initial) to 13.5%, 16.1%, and 18.3% after Poly 400, Poly 200, and Poly 600 flooding respectively. This work highlights the potential of fluorescent polymer microspheres as a valuable tool for EOR applications, offering significant advancements in reservoir management and oil recovery optimization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.