ArticlePloS one2024
Lead acetate-based test strip method for rapid and quantitative detection of residual sulfur dioxide in Chinese herbal medicines.
Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Sulfur fumigation of botanical drugs: impact on chemical composition and pharmacological properties, and advances in detection technologies.Frontiers in pharmacology · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To prevent the residual sulfur dioxide in Chinese herbal medicines (CHM) caused by sulfur fumigation, which may lead to severe health issues, there is an urgent need for a rapid and quantitative detection technique. Sodium borohydride was used as a reducing agent to convert sulfur dioxide into hydrogen sulfide, which was then detected using lead acetate test strip. An accurate testing apparatus was designed, consisting of reaction bottle cap, reaction bottle, lead acetate test strip, and sulfur dioxide detector. The effect of different reaction variables on detection, including reductant quality, pH of initial media, reaction time, lead acetate concentration, and membrane type was investigated. The optimal conditions were determined by orthogonal experiments. The reaction membrane type and lead acetate concentration on the membrane were optimized to enhance detection accuracy. Standardized gray cards were fabricated and used to calibrate the detector. The detection system demonstrated an exceptional linear correlation (r2 = 0.9992), with a linear detection range of 0-750 mg·kg-1. The colored substances and sulfur-containing substances within the matrix of CHM did not affect the detection results. Therefore, the detection method exhibited superior accuracy and stability. The proposed technique proved to be swift, reliable, and provides a straightforward and convenient approach for the quantitative determination of sulfur dioxide in CHMs. The results of this work may provide insights into the development of test strips for quantitative detection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.