ArticleChiropractic & manual therapies2024
Variability and repeatability of spinal manipulation force-time characteristics in thoracic spinal manipulation on a manikin.
Article in Chiropractic & manual therapies, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Biomechanical comparison of lumbar rotational manipulations in two different positions using force measurement and finite element analysis.Chiropractic & manual therapies · 2026Trial
- Efficacy of different biomechanical strategies for modulating force-time parameters of high-velocity low-amplitude manipulation of the thoracic spine: a randomized crossover experimental study.Chiropractic & manual therapies · 2025Trial
- Thoracic spinal manipulation: exploring force-time profiles and force modulation strategies in French chiropractors.Chiropractic & manual therapies · 2026Article
- From mechanotransduction to manual therapy: advances in piezo/TRP channels and lumbar degeneration.Frontiers in physiology · 2026Review
- Force variability of thoracic spine mobilization and manipulation delivered by experienced physiotherapists to healthy human volunteers and a manikin: an observational study.Chiropractic & manual therapies · 2025Observational
- Contextual factors related to aging determine force-based manipulation dosage: a prospective cross-sectional study.Chiropractic & manual therapies · 2025Article
- Chiropractic students' characteristics influencing confidence and competence in modulating spinal manipulation force-time characteristics of specific target forces: a secondary analysis of a cross-sectional study.Chiropractic & manual therapies · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAs part of multimodal therapy, spinal manipulation (SM) is a recommended and effective treatment for musculoskeletal pain. However, the underlying physiological mechanisms for pain relief are largely unknown. SM thrusts can be described and quantified using force-time characteristics (e.g. preload force, peak force, thrust speed, thrust duration, and thrust impulse). If these biomechanical parameters of SM are important for clinical outcomes, a large variability in the delivery of SM could lead to inconsistent responses and could thereby potentially mask a significant clinical effect. Our goal was to determine variability, and repeatability of thoracic spinal manipulation (SM) force-time profiles in a sample of Swiss chiropractors.
methodsAll interventions were performed on a human analogue manikin. Participating chiropractors received three case scenarios with the following scenarios: 50-year-old male patient, 30-year-old male athlete, and a 70-year-old female patient, each presenting with uncomplicated musculoskeletal thoracic pain. Clinicians were asked to perform three consecutive thoracic SM thrusts for each of the scenarios and repeated the same interventions after 24-48 h.
resultsEighty-one chiropractors participated in the study, including 32 females (39.5%) with a mean age of 45.22 ± 12.96 years. The variability in SM force-time characteristics between clinicians was substantial, with preload forces ranging from 4.50 to 450.25 N and peak forces ranging from 146.08 to 1285.17 N. Significant differences between case scenarios were observed for peak force (p < 0.0001), maximum thrust speed (p = 0.0002), and thrust impulse (p = 0.0004). Except for thrust duration, repeatability within and between sessions was fair to excellent (ICCs between 0.578 and 0.957).
conclusionSubstantial variability in application of SM was evident across clinicians and between case scenarios. Despite substantial clinician-dependent variability, the high repeatability of thoracic SM thrusts suggests a level of standardization in SM delivery, indicating that chiropractors might have 'their' individual force-time profile that they are capable to reproduce. Further research based on these findings should explore how to enhance the consistency, effectiveness, and safety of thoracic SM delivered clinically to humans.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.