Evidence map›Paper›PMID 39527001›Full record

ArticleThe Review of scientific instruments2024

Frequency-domain instrument with custom ASIC for dual-slope near-infrared spectroscopy.

Alper Kılıç, Giles Blaney, Fatemeh Tavakoli, Jodee Frias, Angelo Sassaroli, Sergio Fantini, Valencia Koomson

Abstract read
In one paragraph

Article in The Review of scientific instruments, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alper KılıçDepartment of Electrical and Computer Engineering, Tufts University, 161 College Avenue, Medford, Massachusetts 02155, USA.ORCID 0000-0002-6496-236X
Giles BlaneyDepartment of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, USA.ORCID 0000-0003-3419-4547
Fatemeh TavakoliDepartment of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, USA.ORCID 0000-0003-3792-455X
Jodee FriasDepartment of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, USA.ORCID 0000-0002-2626-9441
Angelo SassaroliDepartment of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, USA.ORCID 0000-0003-4233-7165
Sergio FantiniDepartment of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, USA.ORCID 0000-0001-5116-525X
Valencia KoomsonDepartment of Electrical and Computer Engineering, Tufts University, 161 College Avenue, Medford, Massachusetts 02155, USA.ORCID 0000-0003-4043-8309

Funding

Tufts IRACDAK12GM133314 · NIGMS · TUFTS UNIVERSITY BOSTON · PI CLAIRE L MOORE, Jamie Lynn Maguire · 2019 to 2026
$8.4M
Dual-slope method for enhanced depth sensitivity in frequency-domain near-infrared spectroscopyR01EB029414 · NIBIB · TUFTS UNIVERSITY MEDFORD · PI SERGIO FANTINI · 2021 to 2026
$2.5M
NIBIB NIH HHS R01 EB029414NIGMS NIH HHS K12 GM133314
6 · The paper itself

Abstract

Real-time and non-invasive measurements of tissue concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR) are invaluable for research and clinical use. Frequency-domain near-infrared spectroscopy (FD-NIRS) enables non-invasive measurement of these chromophore concentrations in human tissue. We present a small form factor, dual-wavelength, miniaturized FD-NIRS instrument for absolute optical measurements, built around a custom application-specific integrated circuit and a dual-slope/self-calibrating (DS/SC) probe. The modulation frequency is 55 MHz, and the heterodyning technique was used for intensity and phase readout, with an acquisition rate of 0.7 Hz. The instrument consists of a 14 × 17 cm2 printed circuit board (PCB), a Raspberry Pi 4, an STM32G491 microcontroller, and the DS/SC probe. The DS/SC approach enables this instrument to be selective to deeper tissue and conduct absolute measurements without calibration. The instrument was initially validated using a tissue-mimicking solid phantom, and upon confirming its suitability for in vivo, a vascular occlusion experiment on a human subject was conducted. For the phantom experiments, an average of 0.08° phase noise and 0.10% standard deviation over the mean for the intensities was measured at a source-detector distance of 35 mm. The absorption and reduced scattering coefficients had average precisions (variation of measurement over time) of 0.5% and 0.9%, respectively, on a window of ten frames. Results from the in vivo experiment yielded the expected increase in HbO2 and HbR concentration for all measurement types tested, namely SC, DS intensity, and DS phase.

Indexed as

Spectroscopy, Near-InfraredCalibrationEquipment DesignHemoglobinsHumansOxyhemoglobinsPhantoms, ImagingdeoxyhemoglobinHemoglobinsOxyhemoglobins

Identifiers

PMID39527001
PMCPMC11585364

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.