Evidence map›Paper›PMID 39526162›Full record

ArticleJournal of medical physics

A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans.

Muhammad Kabir Abdulkadir, Noor Diyana Osman, Anusha Achuthan, Radin A Nasirudin, Muhammad Zabidi Ahmad, Noor Hasyima Mat Zain, Ibrahim Lutfi Shuaib

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Muhammad Kabir AbdulkadirDepartment of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia.
Noor Diyana OsmanDepartment of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia.
Anusha AchuthanDepartment of Computer Science, School of Computer Science, Universiti Sains Malaysia, Penang, Malaysia.
Radin A NasirudinDepartment of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia.
Muhammad Zabidi AhmadDepartment of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia.
Noor Hasyima Mat ZainDepartment of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia.
Ibrahim Lutfi ShuaibDepartment of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Purpose: Size-specific dose estimates (SSDE) have been introduced into computed tomography (CT) dosimetry to tailor patients' unique sizes to facilitate accurate CT radiation dose quantification and optimization. The purpose of this study was to develop and validate an automated algorithm for the determination of patient size (effective diameter) and SSDE. Materials and Methods: A MATLAB platform was used to develop software of algorithms based on image segmentation techniques to automate the calculation of patient size and SSDE. The algorithm was used to automatically estimate the individual size and SSDE of four CT dose index phantoms and 80 CT images of pediatric patients comprising head, thorax, and abdomen scans. For validation, the American Association of Physicists in Medicine (AAPM) manual methods were used to determine the patient's size and SSDE for the same subjects. The accuracy of the proposed algorithm in size and SSDE calculation was evaluated for agreement with the AAPM's estimations (manual) using Bland-Altman's agreement and Pearson's correlation coefficient. The normalized error, system bias, and limits of agreement (LOA) between methods were derived. Results: The results demonstrated good agreement and accuracy between the automated and AAPM's patient size estimations with an error rate of 1.9% and 0.27% on the patient and phantoms study, respectively. A 1% percentage difference was found between the automated and manual (AAPM) SSDE estimates. A strong degree of correlation was seen with a narrow LOA between methods for clinical study ( Conclusion: The proposed automated algorithm provides an accurate estimation of patient size and SSDE with negligible error after validation.

Indexed as

Algorithmautomationbody sizecomputed tomography scanimage segmentationpediatricradiation dosagesize-specific dose estimate

Identifiers

PMID39526162
PMCPMC11548073

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.