ArticleFood chemistry: X2024
A clenbuterol detection method based on magnetic separation up-conversion fluorescent probe.
Article in Food chemistry: X, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Highly Sensitive Lateral Flow Immunoassay for Clenbuterol and Structurally Similar Beta2-Agonists in Meat.Foods (Basel, Switzerland) · 2025Article
- Recent Progress on Rare-Earth-Doped Upconversion Nanomaterials for Bioassay Applications.Biosensors · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this study, a fluorescence detection method combining aptamer-modified up-conversion nanoparticles (UCNPs) and magnetic nanoparticles (MNPs) was developed for detection of Clenbuterol (CLB). The aptamer-modified magnetic NPs captured CLB, which reacted with the aptamer-modified UCNPs and generated a sandwich complex. The aptamer-modified UCNPs acted as a fluorescence source. The MNP-CLB-UCNP complex was retrieved from the solution using an magnetic field, and the fluorescence intensity was detected by fluorescence spectrophotometry with excitation and emission spectra at 980 nm and in the 400-800 nm region, respectively. The results showed that the fluorescence intensity gradually increased with increasing concentrations of CLB with a good specify. The method was highly sensitive for the quantification of CLB, with a limit of detection of 0.304 ng mL
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.