Evidence map›Paper›PMID 39524863›Full record

ArticleHeliyon2024

Degradation of piroxicam and celecoxib from aqueous solution by high-energy electron beam as a Sustainable method.

Niloufar Borhani Yazdi, Mohammad Rezvani Ghalhari, Ali Parach, Mohammad Hassan Ehrampoush, Kamal Ghadiri, Mahdi Ghorbanian, Mohammad Hossein Zare Hassanabadi, Ehsan Abouee Mehrizi

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Niloufar Borhani YazdiDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Mohammad Rezvani GhalhariDepartment of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Ali ParachDepartment of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Mohammad Hassan EhrampoushDepartment of Environmental Health, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Kamal GhadiriEnvironmental and Occupational Health Research Center, Shahroud University of Medical Sciences, Shahroud, Iran.
Mahdi GhorbanianVector-borne Diseases Research Center, School of Health, North Khorasan University of Medical Sciences, Bojnurd, Iran.
Mohammad Hossein Zare HassanabadiDepartment of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Ehsan Abouee MehriziDepartment of Environmental Health, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Non-steroidal anti-inflammatory drugs (NSAIDs) are one of the most commonly prescribed drugs that can reduce pain. This study aimed to measure the concentration of piroxicam and celecoxib in Iranian hospitals, as well as the effect of electron beam irradiation on the degradation of these pollutants in synthetic and real samples. The high-performance liquid chromatography (HPLC) was used to detect the residual analytes in the samples. The Response Surface Methodology (RSM) was used to design the experiment conditions that investigate the effect of electron beam irradiation on degradation of piroxicam and celecoxib from synthetic samples, and then according to the optimum condition, the experiments were carried out for real wastewater samples. The results of wastewater analysis shown that the mean concentration of PIRO and CELE were 6.32 ± 2.5 and 11.5 ± 3.2 μg/L, respectively. Also, the findings show that 98.98 % and 97.62 % of piroxicam and celecoxib was degraded, respectively, when the optimum conditions (pH = 4, electron beam irradiation = 8 kGy, and concentrations of 60 μg/L for piroxicam and 50 μg/L for celecoxib) were applied. Results show that the degradation rates of piroxicam and celecoxib in the real wastewater sample at optimum condition were 89.6 % and 84.25 %, respectively. So, electron beam irradiation is a long-lasting and promising method for removal emerging contaminants from wastewater, like non-steroidal anti-inflammatory drugs, that can't be removed by conventional wastewater treatment methods; so, it can be used in combination with conventional wastewater treatment methods.

Indexed as

Advanced oxidation processesHigh-energy electron beam irradiationNonsteroidal anti-inflammatory drugsWastewater treatment

Identifiers

PMID39524863
PMCPMC11550070

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.