Evidence map›Paper›PMID 39524287›Full record

ArticleJournal of orthopaedic case reports2024

Surgical Planning and 3D-Printed Mesh Implant for Effective Bone Gap Management: A Case Report.

Avinash Kachare, A B Goregaonkar, Shaligram Purohit, Kishor Munde, Lalhmingmawi Renthlei, Bhanupratap Gaur

Abstract readCase Reports
In one paragraph

Article in Journal of orthopaedic case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Time to consider fracture nonunion an orphan disease? An update into pathophysiology, epidemiology and therapeutic solutions.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Avinash KachareDepartment of Orthopedics, LTMMC and GH, Mumbai, Maharashtra, India.
A B GoregaonkarDepartment of Orthopedics, LTMMC and GH, Mumbai, Maharashtra, India.
Shaligram PurohitDepartment of Orthopedics, LTMMC and GH, Mumbai, Maharashtra, India.
Kishor MundeDepartment of Orthopedics, Medicover Hospital, Chhatrapati Sambhajinagar, Maharashtra, India.
Lalhmingmawi RenthleiDepartment of Pathology, LTMMC and GH, Mumbai, Maharashtra, India.
Bhanupratap GaurBETIC, Mechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Critical-size bone defects in distal tibial open wounds pose a formidable challenge, requiring interventions that can address osseous reconstruction with less number of surgeries. Current treatment modalities may fall short in achieving optimal outcomes, with respect to early weight bearing due to the inability of the graft to sustain weight, graft-related infections, non-union in large defects, donor site morbidity, and non-availability of bone grafts due to earlier harvest. This case report explores the potential application of a 3D-printed mesh implant to this complex clinical scenario. Case Report: A 38-year-old male, post-road traffic accident, presented with an inability to walk due to fractures of the medial malleolus and distal tibia-fibula with a grade 3b open wound. Initial treatment was done with an external fixator and fibula plating, with the fixator removed after 5 months. The fracture showed atrophic non-union and a 2.5 cm limb shortening at the end of 5 months. Preferring thick flap incisions, the patient operated with a 3D-printed titanium mesh implant with a plate construct. Post-surgery, we followed a non-weight-bearing regime for 1.5 months, progressing to full weight-bearing by 3 months. At 1.5 years, CT scans confirmed good bone integration and ambulation restoration. Conclusion: The use of 3D-printed mesh implants may be a viable option for managing critical-size bone defects in distal tibial open wounds. Porotic nature of mesh implant facilitates bone ingrowth in large gaps.

Indexed as

3D-printingmesh implantnon-union

Identifiers

PMID39524287
PMCPMC11546020

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.