ArticleVascular health and risk management2024

Clinical Accuracy of the G.LAB MD41A0 Upper Arm Blood Pressure Monitor in Pregnancy and Pre-Eclampsia Using the AAMI/ESH/ISO as Reference Standard.

Ying Zhang, Ziyun Shi, Haixia Liang, Meixia Chen, Yan Sun, Fujun Shang, Yi Wan

Abstract readValidation Study
In one paragraph

Article in Vascular health and risk management, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ying Zhang *Department of Obstetrics and Gynecology, Xijing 986 hospital, Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China.
Ziyun Shi *Department of Obstetrics, Shaanxi Provincial People's Hospital, Xi'an, Shaanxi, People's Republic of China.
Haixia LiangDepartment of Obstetrics and Gynecology, Xijing 986 hospital, Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China.
Meixia ChenDepartment of Obstetrics and Gynecology, Xijing 986 hospital, Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China.
Yan SunDepartment of Obstetrics and Gynecology, Xijing 986 hospital, Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China.
Fujun ShangDepartment of Cardiology, Xi'an Gem Flower Changqing Hospital, Xi'an, Shaanxi, People's Republic of China.
Yi WanDepartment of Health Service, Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China.ORCID 0000-0002-4125-8396

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Validation of blood pressure (BP) monitors in pregnant women are needed to ensure the accurate measurement of BP in pregnancy. Therefore the study aimed to evaluate the measurement accuracy of the G.LAB MD41A0 oscillometric automatic upper-arm blood pressure monitor in pregnancy and pre-eclampsia women according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018). Methods: A total of 45 pregnant women were included in the cross-sectional validation study. The same left-arm sequential method was used for blood pressure measurement, and the blood pressure differences between the test device and the mercury standard reference were assessed according to the AAMI/ESH/ISO Universal Standard. Results: The participants included 15 normotensives, 15 gestational hypertension and 15 pre-eclampsia. The average (mean ± SD) differences between the device and mercury standard was -0.84±3.88 mmHg and -0.58±3.35 mmHg for systolic and diastolic blood pressure, respectively, for the validation Criterion 1. The SD of the averaged differences between the device and reference readings per participant was 2.92 mmHg and 2.28 mmHg for systolic and diastolic blood pressure, respectively, for the Criterion 2 of the universal standard. Conclusion: The G.LAB MD41A0 automatic upper-arm blood pressure monitor fulfills the criteria of the AAMI/ESH/ISO Universal Standard and can be recommended for clinical use and self-measurement in pregnancy and pre-eclampsia.

Indexed as

Blood PressureBlood Pressure DeterminationBlood Pressure MonitorsPredictive Value of TestsPre-EclampsiaAdultArmCross-Sectional StudiesEquipment DesignFemaleHumansHypertension, Pregnancy-InducedOscillometryPregnancyReproducibility of ResultsYoung Adultblood pressure monitorpre-eclampsiapregnancyuniversal standardvalidation

Identifiers

PMID39524156
PMCPMC11549012

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.