Trial reportJournal of clinical monitoring and computing2025
Evaluation of decision support to wean patients from mechanical ventilation in intensive care: a prospective study reporting clinical and physiological outcomes.
Trial report in Journal of clinical monitoring and computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03249623 (Weaning From Mechanical Ventilation), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Weaning From Mechanical Ventilation: Comparison of Open-Loop Decision Support System and Routine Care, in the General Intensive Care Unit
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study investigated the clinical and physiological response to use of the BEACON Caresystem, a bedside open-loop decision support system providing advice to guide clinicians when weaning patients from invasive mechanical ventilation. Multicenter prospective study conducted in five adult intensive care units in the UK. Following screening and assent, intubated patients mechanically ventilated for > 24 h were randomized to intervention or usual care. Intervention consisted of application of the BEACON Caresystem's advice on tidal volume/inspiratory pressure, inspired oxygen, respiratory rate and PEEP. Usual care was defined as local clinical practice. The primary outcome was duration of mechanical ventilation. Secondary outcomes quantified prolonged intubation and survival; adverse events; ventilator settings and physiological state; time spent in ventilator modes; links to other therapy; the frequency of advice utilization and time spent outside normal physiological limits. The study was terminated early with a total of 112 patients included. Fifty-four were randomised to the intervention arm and fifty-eight to usual care. The study was underpowered and no significant differences were seen in duration of mechanical ventilation (p = 0.773), prolonged intubation or survival. Intervention arm patients had lower rates of adverse events (p = 0.016), including fewer hypoxaemic events (p = 0.008) and lower values of PEEP (p = 0.030) and tidal volume (p = 0.042). Values of peak inspiratory pressure and pressure support were reduced but at the boarder of statistical significance (p = 0.104, p = 0.093, respectively). No differences were seen for time in ventilator mode or other therapy. Advice presented by the decision support system was applied at the beside an average of 88% of occasions, with a significantly increased number of changes only in inspired oxygen fraction. No significant differences were seen in time spent outside physiological limits. This study investigated the use of the BEACON Caresystem, an open loop clinical decision support system providing advice on ventilator settings. It was terminated early, with no significant difference shown in duration of mechanical ventilation, the primary outcome. Application of advice indicated potential for fewer adverse events and improved physiological status. (Trial registration ClinicalTrials.gov under NCT03249623. Registered 22nd June 2017).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials