Evidence map›Paper›PMID 39517988›Full record

ArticleSensors (Basel, Switzerland)2024

Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty.

John E Farey, Yuan Chai, Joshua Xu, Vincent Maes, Ameneh Sadeghpour, Neri A Baker, Jonathan M Vigdorchik, William L Walter

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

John E FareySydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia.
Yuan ChaiSydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia.ORCID 0000-0001-6977-6155
Joshua XuDepartment of Orthopedics and Traumatic Surgery, Royal North Shore Hospital, St Leonards, NSW 2065, Australia.ORCID 0000-0001-7598-6482
Vincent MaesSydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia.ORCID 0000-0002-6345-1998
Ameneh SadeghpourInnovation Department, Navbit, Sydney, NSW 2000, Australia.
Neri A BakerInnovation Department, Navbit, Sydney, NSW 2000, Australia.
Jonathan M VigdorchikAdult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY 10021, USA.
William L WalterSydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2) Methods: Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3) Results: For inclination, the mean absolute error (MAE) was lower using the TT method (2.4° ± 1.7°) compared to the ASIS (2.8° ± 1.7°,

Indexed as

AcetabulumArthroplasty, Replacement, HipSurgery, Computer-AssistedAgedFemaleHumansImaging, Three-DimensionalMaleMiddle AgedSurgical Navigation SystemsTomography, X-Ray Computedacetabular orientationcomputer assisted surgeryimageless navigationimplant accuracyoptical sensorregistration planetotal hip arthroplasty

Identifiers

PMID39517988
PMCPMC11548659

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.