ArticleSensors (Basel, Switzerland)2024
Method for Extracting Optical Element Information Using Optical Coherence Tomography.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
Abstract
This study examines the measurement of film thickness, curvature, and defects on the surface or inside of an optical element using a highly accurate and efficient method. This is essential to ensure their quality and performance. Existing methods are unable to simultaneously extract the three types of information: thickness, curvature, and defects. Spectral-domain optical coherence tomography (SD-OCT), a non-invasive imaging technique with imaging depths down to the millimeter scale, provides the possibility of detecting the optical element components' parameters. In this paper, we propose an error correction model for compensating delay differences in A-scan, field curvature, and aberration to improve the accuracy of system fitting measurements using SD-OCT. During data processing, we use the histogram-equalized gray stretching (IAH-GS) method to deal with strong reflections in the thin film layers inside the optics using individual A-scan averages. In addition, we propose a window threshold cutoff algorithm to accurately identify defects and boundaries in OCT images. Finally, the system is capable of rapidly detecting the thickness and curvature of film layers in optical elements with a maximum measurement depth of 4.508 mm, a diameter of 15 × 15 mm, a resolution of 5.69 microns, and a sampling rate of 70 kHz. Measurements were performed on different standard optical elements to verify the accuracy and reliability of the proposed method. To the best of our knowledge, this is the first time that thickness, curvature, and defects of an optical film have been measured simultaneously, with a thickness measurement accuracy of 1.924 µm, and with a difference between the calibrated and nominal curvature measurements consistently within 1%. We believe that this research will greatly advance the use of OCT technology in the testing of optical thin films, thereby improving productivity and product quality.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.