Evidence map›Paper›PMID 39517780›Full record

ArticleSensors (Basel, Switzerland)2024

Image Quality Comparison of Three 3D Mobile X-Ray Imaging Guidance Devices Used in Spine Surgery: A Phantom Study.

Djamel Dabli, Cécile Salvat, Isabelle Fitton, Claire Van Ngoc Ty, Peggy Palanchon, Jean-Paul Beregi, Joël Greffier, Lama Hadid-Beurrier

Abstract readComparative Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Djamel DabliDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nimes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.ORCID 0000-0003-1003-1196
Cécile SalvatMedical Physics and Radiation Protection Department, APHP Lariboisière University Hospital, 75010 Paris, France.
Isabelle FittonDepartment of Radiology, Georges Pompidou European Hospital, Paris Cité University, APHP, 75015 Paris, France.ORCID 0000-0003-3360-9798
Claire Van Ngoc TyDepartment of Radiology, Georges Pompidou European Hospital, Paris Cité University, APHP, 75015 Paris, France.ORCID 0000-0001-7241-6361
Peggy PalanchonDepartment of Radiodiagnostics, CHU Angers, 4 Rue Larrey, 49933 Angers, France.
Jean-Paul BeregiDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nimes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
Joël GreffierDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nimes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.ORCID 0000-0002-1735-5129
Lama Hadid-BeurrierMedical Physics and Radiation Protection Department, APHP Lariboisière University Hospital, 75010 Paris, France.ORCID 0000-0001-9458-6150

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An image-quality CT phantom was scanned with three different 3D X-ray imaging guidance devices in the operating theatre: O-Arm, Loop-X, and Airo TruCT. Default acquisition and reconstruction parameters for lumbar spine procedures were used on each device. The tube current was set to a dose level of around 27 mGy. A task-based image quality assessment was performed by calculating the noise power spectrum (NPS) and task transfer function (TTF). A detectability index (d') was calculated for three simulated bone lesions. The noise magnitude of the O-Arm was higher than the Airo TruCT, and the Loop-X had higher noise than the Airo TruCT. The highest average NPS frequency was for the O-Arm images, and the lowest was for the Loop-X. The TTFs at 50% values were similar for the Airo TruCT and Loop-X devices. Compared to Airo TruCT, the TTF at 50% value increased with the O-Arm by 53.12% and 41.20% for the Teflon and Delrin inserts, respectively. Compared to Airo TruCT, the d' value was lower with Loop-X by -26.73%, -27.02%, and -23.95% for lytic lesions, sclerotic lesions, and high-density bone, respectively. Each 3D-imaging spine surgery guidance device has its own strengths and weaknesses in terms of image quality. Cone-beam CT systems apparently offer the best compromise between noise and spatial resolution for spine surgery.

Indexed as

Imaging, Three-DimensionalPhantoms, ImagingSpineTomography, X-Ray ComputedHumansSurgery, Computer-Assisted3D imagingnoise power spectrumspine surgerytask transfer function

Identifiers

PMID39517780
PMCPMC11548279

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.