A Non-Contacted Height Measurement Method in Two-Dimensional Space.

Phu Nguyen Trung, Nghien Ba Nguyen, Kien Nguyen Phan, Ha Pham Van, Thao Hoang Van, Thien Nguyen, Amir Gandjbakhche

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Phu Nguyen TrungFaculty of Information Technology, Hanoi University of Industry, No. 298 Cau Dien, Bac Tu Liem, Hanoi 143510, Vietnam.
Nghien Ba NguyenFaculty of Information Technology, Hanoi University of Industry, No. 298 Cau Dien, Bac Tu Liem, Hanoi 143510, Vietnam.ORCID 0000-0002-5292-6302
Kien Nguyen PhanSchool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hai Ba Trung, Hanoi 100000, Vietnam.ORCID 0000-0003-3175-2937
Ha Pham VanFaculty of Information Technology, Hanoi University of Industry, No. 298 Cau Dien, Bac Tu Liem, Hanoi 143510, Vietnam.
Thao Hoang VanSchool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hai Ba Trung, Hanoi 100000, Vietnam.
Thien NguyenEunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892-4480, USA.
Amir GandjbakhcheEunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892-4480, USA.ORCID 0000-0003-2652-0162

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Height is an important health parameter employed across domains, including healthcare, aesthetics, and athletics. Numerous non-contact methods for height measurement exist; however, most are limited to assessing height in an upright posture. This study presents a non-contact approach for measuring human height in 2D space across different postures. The proposed method utilizes computer vision techniques, specifically the MediaPipe library and the YOLOv8 model, to analyze images captured with a smartphone camera. The MediaPipe library identifies and marks joint points on the human body, while the YOLOv8 model facilitates the localization of these points. To determine the actual height of an individual, a multivariate linear regression model was trained using the ratios of distances between the identified joint points. Data from 166 subjects across four distinct postures: standing upright, rotated 45 degrees, rotated 90 degrees, and kneeling were used to train and validate the model. Results indicate that the proposed method yields height measurements with a minimal error margin of approximately 1.2%. Future research will extend this approach to accommodate additional positions, such as lying down, cross-legged, and bent-legged. Furthermore, the method will be improved to account for various distances and angles of capture, thereby enhancing the flexibility and accuracy of height measurement in diverse contexts.

Indexed as

Body HeightPostureAdultAlgorithmsFemaleHumansImage Processing, Computer-AssistedMaleSmartphoneYoung Adultheight measurementMediaPipenon-contact

Identifiers

PMID39517693
PMCPMC11548123

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.