Evidence map›Paper›PMID 39516466›Full record

ArticleMicrosystems & nanoengineering2024

Piezoelectric MEMS microphones based on rib structures and single crystal PZT thin film.

Zhiwei You, Jinghan Gan, Chong Yang, Renati Tuerhong, Lei Zhao, Yipeng Lu

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhiwei YouSchool of Integrated Circuits, Peking University, Beijing, China.ORCID http://orcid.org/0000-0001-6205-9962
Jinghan GanSchool of Integrated Circuits, Peking University, Beijing, China.
Chong YangSchool of Integrated Circuits, Peking University, Beijing, China.
Renati TuerhongSchool of Integrated Circuits, Peking University, Beijing, China.
Lei ZhaoSchool of Integrated Circuits, Peking University, Beijing, China.
Yipeng LuSchool of Integrated Circuits, Peking University, Beijing, China. yplu@pku.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, a controllable mass‒frequency tuning method is presented using the etching of rib structures on a single-crystal PZT membrane. The rib structures were optimized to reduce the membrane mass while maintaining the stiffness; therefore, the center frequency could be increased to improve the low-frequency bandwidth of microphones. Additionally, this methodology could reduce the modulus and improve the sensitivity for the same resonant frequency, which typically indicates the maximum acoustic overload point (AOP). The PZT film was chosen because of its greater density; the simulation results showed that PZT could provide a greater frequency tuning (24.9%) compared to that of the AlN film (5.8%), and its large dielectric constant enabled the optimal design to have small electrodes at the maximum stress location while mitigating the sacrificial capacitance effect on electrical gain. An analytical model of rib-structure microphones was established and greatly reduced the computing time. The experimental results of the impedance tests revealed that the center frequencies of the six microphones shifted from 74.6 kHz to 106.3 kHz with rib-structure inner radii ranging from 0 μm to 340 μm; this result was in good agreement with the those of the analytical analysis and finite element modeling. While the center frequency greatly varied, the measured sensitivities at 1 kHz only varied within a small range from 22.3 mV/Pa to 25.7 mV/Pa; thus, the membrane stiffness minimally changed. Moreover, a single-crystal PZT film with a (100) crystal orientation and 0.24-degree full width at half maximum (FWHM) was used to enable differential sensing and a low possibility of undesirable polarization. Paired with a two-stage differential charge amplifier, a differential sensing microphone was experimentally demonstrated to improve the sensitivity from 25.7 mV/Pa to 36.1 mV/Pa and reduce the noise from -68.2 dBV to -82.8 dBV.

Identifiers

PMID39516466
PMCPMC11549332

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.