ArticleInternational journal of spine surgery2024
Nonmetallic Carbon Fiber-Reinforced Polyetheretherketone Implants Vs Titanium Implants: Analysis of Clinical Outcomes and Influence on Postoperative Radiotherapy Planning in Metastatic Spine Tumor Surgery.
Article in International journal of spine surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Carbon fiber-PEEK pedicle screw instrumentation in spinal oncology: a retrospective case series, systematic review of the literature, and cost-effectiveness analysis.Journal of neuro-oncology · 2026Pooled it
- Carbon fiber-reinforced polyetheretherketone implants versus titanium implants for spinal tumors: a systematic review and meta-analysis.Journal of neuro-oncology · 2026Pooled it
- Comparison of Titanium and Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants in Postoperative Spine Stereotactic Body Radiation Therapy: A Comprehensive Review of Current Evidence and Future Perspectives.Advances in radiation oncology · 2026Review
- Three dimensional printed patient-specific PEEK versus titanium mesh cage for anterior column reconstruction after spondylectomy for spinal tumours: a prospective controlled cohort study.International orthopaedics · 2026Article
- Safety and efficacy of carbon fiber-reinforced polyetheretherketone implants in primary and metastatic spinal tumors: a systematic review and meta-analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Review
- Article
- Material and Geometric Innovations in Lumbar and Cervical Interbody Devices: A Systematic Scoping Review.Annals of biomedical engineering · 2026Review
- Robot-Assisted Placement of Thoracic Carbon-Fiber-Reinforced Polyetheretherketone (CFR-Peek) Pedicle Screws in the Cervical Spine for Giant Cell Tumor: Technical Note.Bioengineering (Basel, Switzerland) · 2026Article
- Shaping the future of spinal implants: advancing bioactive composites with 3D printing for next-generation surgical care.Journal of orthopaedic surgery and research · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTitanium has been the conventional implant material of choice for fixation in both primary and metastatic spine tumor surgeries (MSTS). However, these implants result in artifact generation during postoperative computed tomography or magnetic resonance imaging, resulting in poor planning of radiotherapy (RT) and suboptimal tumor surveillance. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) implants have gained momentum for instrumentation in MSTS due to their radiolucent properties. In this study, the perioperative outcomes, postoperative imaging artifacts, and dosimetric data of CFR-PEEK implants to titanium implants were compared to assess for potential benefits in postoperative RT planning in patients undergoing MSTS.
methodsThis is a retrospective study involving 62 patients who underwent operations for MSTS. The cohort of CFR-PEEK fixations (
resultsBoth groups had similar clinical outcomes for pain and overall survival predictability preoperatively (
conclusionOur study confirms that CFR-PEEK screws significantly reduce artifact generation and the time taken to contour them during postoperative RT planning while delivering equivalent clinical and functional outcomes as compared with standard titanium implants. LEVEL OF EVIDENCE: 2: