Evidence map›Paper›PMID 39514033›Full record

ArticleNeuroradiology2024

Real-time measurement of radiation exposure in interventional radiologists during CT-guided intrathecal injections of nusinersen.

Grzegorz Rosiak, Jakub Franke, Krzysztof Milczarek, Dariusz Konecki, Anna Frączek-Kozlovska, Anna Potulska-Chromik, Anna Kostera-Pruszczyk, Anna Łusakowska

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Grzegorz RosiakII Department of Radiology, Medical University of Warsaw, Warsaw, Poland.ORCID http://orcid.org/0000-0002-0833-7527
Jakub FrankeII Department of Radiology, Medical University of Warsaw, Warsaw, Poland. jakub.t.franke@gmail.com.ORCID http://orcid.org/0000-0002-2661-1446
Krzysztof MilczarekII Department of Radiology, Medical University of Warsaw, Warsaw, Poland.ORCID http://orcid.org/0000-0003-0022-4867
Dariusz KoneckiII Department of Radiology, Medical University of Warsaw, Warsaw, Poland.ORCID http://orcid.org/0000-0002-9874-9137
Anna Frączek-KozlovskaDepartment of Neurology, Medical University of Warsaw, ERN EURO NMD, Banacha 1a, Warsaw, 02-097, Poland.ORCID http://orcid.org/0000-0002-6260-6839
Anna Potulska-ChromikDepartment of Neurology, Medical University of Warsaw, ERN EURO NMD, Banacha 1a, Warsaw, 02-097, Poland.ORCID http://orcid.org/0000-0002-8332-1090
Anna Kostera-PruszczykDepartment of Neurology, Medical University of Warsaw, ERN EURO NMD, Banacha 1a, Warsaw, 02-097, Poland.ORCID http://orcid.org/0000-0002-7309-1914
Anna ŁusakowskaDepartment of Neurology, Medical University of Warsaw, ERN EURO NMD, Banacha 1a, Warsaw, 02-097, Poland.ORCID http://orcid.org/0000-0003-1909-9963

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSome patients with spinal muscular atrophy and scoliosis require CT guidance during injections of nusinersen. The radiation applied to the operator in such procedures becomes an important issue in terms of staff health and safety. The aim of the study was to assess the operator's radiation exposure during CT-guided nusinersen injections in patients with spinal muscular atrophy and scoliosis.

methodsConsecutive 40 CT-guided nusinersen injections were analyzed in terms of operator's radiation exposure measured in real time.

resultsThe median radiation dose measured under the physician's lead apron and patient dose in terms of DLP was 0.20 µSv and 31.90 mGy*cm respectively. The radiation doses were significantly higher (p = 0.047) in patients with spinal instrumentation.

conclusionThe results show that CT-guided nusinersen injection is a relatively safe procedure in terms of operator's radiation exposure. This can allow for interventional radiologists to perform more procedures without exceeding their annual dose limit.

Indexed as

Injections, SpinalMuscular Atrophy, SpinalOccupational ExposureOligonucleotidesRadiation ExposureRadiography, InterventionalTomography, X-Ray ComputedAdolescentAdultChildFemaleHumansMaleMiddle AgedRadiation DosageScoliosisnusinersenOligonucleotidesCT-guided spinal injectionNusinersenRadiation exposureSpinal muscular atrophy

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.