ArticleCardiovascular diagnosis and therapy2024

Efficacy and safety of leadless ventricular pacemaker: a single-center retrospective observational study.

Lin Yan, Lin Ling, Yumeng Song, Tingbo Jiang

Abstract read
In one paragraph

Article in Cardiovascular diagnosis and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lin YanDepartment of Cardiology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Lin LingDepartment of Cardiology, The First Affiliated Hospital of Soochow University, Suzhou, China.
Yumeng SongDepartment of Critical Care Medicine, Shanghai Sixth People's Hospital, Shanghai, China.
Tingbo JiangDepartment of Cardiology, The First Affiliated Hospital of Soochow University, Suzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The Micra leadless pacemaker (MLP) has been demonstrated to be safe and effective as a substitute for conventional transvenous ventricular pacemakers (TVP). However, its application in the general population is still restricted. The aim of this retrospective study was to assess the safety and efficacy of MLP. Methods: Clinical data and device parameters were gathered on every patient receiving MLP implantation between 1 January 2019 and 31 December 2023, in the First Affiliated Hospital of Soochow University. The efficacy of MLP on the primary composite endpoint, atrioventricular (AV) synchrony, hospitalization, and post-implantation quality of life was assessed. Safety outcomes included implantation procedural characteristics, acute and chronic complications, and stability of pacing parameters. Meanwhile, we compared pacing parameters, AV synchrony, and improvement of life quality between patients who had been implanted with the MicraTM VR (Medtronic Micra™ MC1VR01) and Micra™ AV (Medtronic Micra™ MC1AVR1). Multivariate linear regression models were used to unearth potential predictors of echocardiography or electrocardiogram (ECG) parameters on pacing parameters. Results: A total of 94 patients were included, and implantation was successful in all of the cases. A single patient experienced effusion hours after the implantation, indicating a low rate of both acute and chronic complications. In patients with complete AV block (AVB), Micra AV increased AV synchrony from 23.2%±6.3% to 80.8%±5.7%. After 28 days of implantation, the patients' Minnesota Living with Heart Failure Questionnaire (MLHFQ) score decreased from 27.1±18.6 to 20.0±17.6, and none of them required hospital readmission. Left ventricular end-diastolic diameter (LVEDD, 50.0±6.7 cm), left ventricular end-systolic diameter (LVESD, 32.6±3.9 cm), and ECG R wave in lead V5 (RV5, 1.3±0.6 mV) can be employed for the prediction of pacemaker threshold [0.50 (0.38-0.67) mV], sensing voltage (10.1±4.7 mV), and impedance (785.9±226.4 Ohm) correspondingly. Conclusions: Despite being a small, single-center, retrospective study, our study provided data for assessing the safety and efficacy of MLP. Clinicians and patients can make well-informed therapy decisions by being aware of its benefits and forecasting pacing parameters.