Evidence map›Paper›PMID 39511015›Full record

ArticleJournal of imaging informatics in medicine2025

Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy.

Yuhei Koike, Hideki Takegawa, Yusuke Anetai, Satoaki Nakamura, Ken Yoshida, Asami Yoshida, Midori Yui, Kazuki Hirota, Kenichi Ueda, Noboru Tanigawa

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yuhei KoikeDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan. koikeyuh@hirakata.kmu.ac.jp.ORCID http://orcid.org/0000-0003-3963-4257
Hideki TakegawaDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Yusuke AnetaiDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Satoaki NakamuraDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Ken YoshidaDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Asami YoshidaDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Midori YuiDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Kazuki HirotaDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Kenichi UedaDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Noboru TanigawaDepartment of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.

Funding

Japan Society for the Promotion of Science 23K14931
6 · The paper itself

Abstract

Cone-beam computed tomography (CBCT) is widely utilized in image-guided radiation therapy; however, its image quality is poor compared to planning CT (pCT), thus restricting its utility for adaptive radiotherapy (ART). Our objective was to enhance CBCT image quality utilizing a transformer-based deep learning model, SwinUNETR, which we compared with a conventional convolutional neural network (CNN) model, U-net. This retrospective study involved 260 patients undergoing prostate radiotherapy, with 245 patients used for training and 15 patients reserved as an independent hold-out test dataset. Employing a CycleGAN framework, we generated synthetic CT (sCT) images from CBCT images, employing SwinUNETR and U-net as generators. We evaluated sCT image quality and assessed its dosimetric impact for photon therapy through gamma analysis and dose-volume histogram (DVH) comparisons. The mean absolute error values for the CT numbers, calculated using all voxels within the patient's body contour and taking the pCT images as a reference, were 84.07, 73.49, and 64.69 Hounsfield units for CBCT, U-net, and SwinUNETR images, respectively. Gamma analysis revealed superior agreement between the dose on the pCT images and on the SwinUNETR-based sCT plans compared to those based on U-net. DVH parameters calculated on the SwinUNETR-based sCT deviated by < 1% from those in pCT plans. Our study showed that, compared to the U-net model, SwinUNETR could proficiently generate more precise sCT images from CBCT images, facilitating more accurate dose calculations. This study demonstrates the superiority of transformer-based models over conventional CNN-based approaches for CBCT-to-CT translation, contributing to the advancement of image synthesis techniques in ART.

Indexed as

Cone-Beam Computed TomographyDeep LearningProstatic NeoplasmsRadiotherapy, Image-GuidedHumansMaleNeural Networks, ComputerRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective StudiesAdaptive radiotherapyCBCTDeep learningProstate cancerTransformer

Identifiers

PMID39511015
PMCPMC12344053

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.