ArticlePLoS medicine2024
The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry.
Article in PLoS medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Ceramic-on-ceramic versus polyethylene-based bearings in total hip arthroplasty: a meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Pooled it
- Pooled it
- Comparative outcomes of delta-on-delta and delta-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a nationwide cohort study.Archives of orthopaedic and trauma surgery · 2026Article
- Cumulative revision rates in total hip arthroplasty depending on acetabular cup fixation: an analysis from the German arthroplasty registry.Arthroplasty (London, England) · 2026Article
- Metal-on-metal hip implants: Revisiting degradation product chemistry and molecular mechanisms of ARMD.Biomaterials and biosystems · 2026Review
- Mid- to long-term outcomes and survival of total hip arthroplasty using a Kerboull-type acetabular reinforcement plate: an analysis of associated factors.Archives of orthopaedic and trauma surgery · 2026Article
- Impact of Anemia on Outcomes Following Total Hip Replacement Surgery and Patient Prognosis.Orthopaedic surgery · 2026Review
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe risk of re-operation, otherwise known as revision, following primary hip replacement depends in part on the prosthesis implant materials used. Current performance evidences are based on a broad categorisation grouping together different materials with potentially varying revision risks. We investigated the revision rate of primary total hip replacement (THR) reported in the National Joint Registry by specific types of bearing surfaces used. METHODS AND
findingsWe analysed THR procedures across all orthopaedic units in England and Wales. All patients who received a primary THR between 2003 and 2019 in the public and private sectors were included. We investigated the all-cause and indication-specific risks of revision using flexible parametric survival analyses to estimate adjusted hazard ratios (HRs). We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with head and shell/liner combinations. A total of 1,026,481 primary THRs were analysed (Monobloc: n = 378,979 and Modular: n = 647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n = 7,381 and Modular: n = 13,488). For monobloc implants, compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the all-cause risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome (hazard rate at 10 years after surgery: 1.28 95% confidence intervals [1.10, 1.48]) or stainless steel head (1.18 [1.02, 1.36]) and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any postoperative period (1.18 [1.02, 1.36]). For modular implants, compared to patients with a cobalt chrome head and HCLPE liner primary THR, the all-cause risk of revision for modular acetabular implant varied non-constantly. THRs with a delta ceramic (0.79 [0.73, 0.85]) or oxidised zirconium (0.65 [0.55, 0.77]) head and HCLPE liner had a lower risk of revision throughout the entire postoperative period. Similar results were found when investigating the indication-specific risks of revision for both the monobloc and modular acetabular implants. While this large, nonselective analysis is the first to adjust for numerous characteristics collected in the registry, residual confounding cannot be rule out.
conclusionsProsthesis revision is influenced by the prosthesis materials used in the primary procedure with the lowest risk for implants with delta ceramic or oxidised zirconium head and an HCLPE liner/cup. Further work is required to determine the association of implant bearing materials with the risk of rehospitalisation, re-operation other than revision, mortality, and the cost-effectiveness of these materials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.