Potential Sampling Errors in Stability Studies Due to Dead Volume in Closed System Transfer Devices.

Mélanie Closset, Maire-Lise Colsoul, Benoît Bihin, Jean-Daniel Hecq, Pascal Odou, Laurence Galanti

Abstract readCase Reports
In one paragraph

Article in The Journal of pharmacy technology : jPT : official publication of the Association of Pharmacy Technicians, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mélanie ClossetMedical Laboratory, CHU UCL NAMUR, Yvoir, Belgium.ORCID https://orcid.org/0000-0002-0553-1981
Maire-Lise ColsoulMedical Laboratory, CHU UCL NAMUR, Yvoir, Belgium.
Benoît BihinDrug Stability Research Group, CHU UCL NAMUR, Yvoir, Belgium.ORCID https://orcid.org/0000-0002-8713-6319
Jean-Daniel HecqDrug Stability Research Group, CHU UCL NAMUR, Yvoir, Belgium.
Pascal OdouUniversity of Lille, CHU Lille, URL7365 - GRITA - Groupe de Recherche sur les formes Injectables et les Technologies Associées, Lille, France.
Laurence GalantiMedical Laboratory, CHU UCL NAMUR, Yvoir, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Closed system transfer devices (CSTD) help to reduce the exposure of healthcare professionals to hazardous drugs. They may be used in stability studies conducted on anticancer drugs. During a stability study about polyolefin bags of gemcitabine, Tevadaptor® device was suspected of causing a bias in the evaluation of the concentrations of the first aliquots extracted from the bags. Objective: The objectives are to determine whether the use of a CSTD to prepare a drug solution and to withdraw it from a bag can interfere on the measured concentration compared to the expected one and to suggest hypothesis to explain the phenomenon. Method: In the first experiment, three polyolefin bags of gemcitabine (5.4 mg/mL) were prepared under aseptic conditions using the Tevadaptor Luer Lock Adaptor®. The day of preparation, five aliquots of 3.8 ml each were sequentially withdrawn from each polyolefin bag using the same device. After one day, a new aliquot was withdrawn from each bag. In the second experiment, three polyolefin bags of gemcitabine (5.4 mg/ml) were prepared under aseptic conditions using a needle. One aliquot was extracted using a needle after the preparation from each bag, and another aliquot was extracted after one day. The concentrations of all aliquots were measured by liquid chromatography coupled to a photodiode array detector during the same run. Results and discussion: The concentrations of the first aliquots extracted on day zero from the polyolefin bags using the Tevadaptor Luer Lock Adaptor® exhibit an overestimation of 26% ([95%CI: 23%-29%] P<0.001) compared to the others. Overestimation is not found for subsequent aliquots, or while using a needle to bypass the Tevadaptor® device. Conclusion: This case highlights the bias that may arise when using CSTDs in stability studies. They should be used with comprehensive understanding of their technical specifications.

Indexed as

Anticancer drugClosed system transfer device (CSTD)Liquid chromatographyStability studyTevadaptor®

Identifiers

PMID39507876
PMCPMC11536552

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.