Evidence map›Paper›PMID 39506778›Full record

ArticleBMC musculoskeletal disorders2024

Novel hook plate for radial semilunar lip facet fragment fixation: a finite element analysis.

Leonardo Rigobello Battaglion, Henrique de Barros Pinto Netto, Ana Paula Macedo, Jose Batista Volpon, Antonio Carlos Shimano

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Leonardo Rigobello BattaglionLaboratory of Bioengineering, Department of Orthopedics and Anesthesiology, School of Medicine of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil. leonardo.rigobello@usp.br.ORCID http://orcid.org/0000-0003-0432-8487
Henrique de Barros Pinto NettoOrthopedics and hand surgery service, Hospital Federal da Lagoa, Rio de Janeiro, RJ, Brazil.
Ana Paula MacedoDepartment of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
Jose Batista VolponLaboratory of Bioengineering, Department of Orthopedics and Anesthesiology, School of Medicine of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
Antonio Carlos ShimanoLaboratory of Bioengineering, Department of Orthopedics and Anesthesiology, School of Medicine of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intra-articular fractures of the distal radius require anatomical reduction and stable fixation. When the fracture encompasses the articular facet of the bone, maintaining the reduction is challenging due to the fragment's size and high instability. While specific implants have been developed to fix this fragment, their effectives have been limited. This study evaluates the mechanical performance of a novel hook plate conceived to stabilize the small fragment of the semilunar facet of the radius in non-osteoporotic bones. A simulated lunate facet fracture was created in an adult radius in a virtual model, and a modification of a hook plate was developed using computer-aided design (CAD). Two groups were established for the finite element method (FEM) simulation: a control group (standard plate Medartis™ (Switzerland, A-5500.23) and an angled plate with hooks set at 60º, 90º and 120º. In the FEM simulation, an axial load of 100 N was applied in the Z-axis direction on the fragment. Fracture displacement along the Z axis was more pronounced in the control model (0.32 mm) and less in the angled models, ranging from 0.22 to 0.28 mm. Notably, the plate with a 90° angle showed a more effective reduction in fragment displacement. The distribution of stresses in the system showed the highest levels of stress in the control group (59.31 MPa), followed by the subgroup with a 60° angle (55.78 MPa).In the side view, the control model showed a higher concentration of stresses (59.74 MPa), while the model with a 90° angle showed a lower value of stresses (18.87 MPa). Critical stress regions were identified in the bolts of the control and 120° models (59.47 MPa and 57.64 MPa, respectively). However, in the 90° model, no critical regions were observed in the bolts, which showed lower stress values, reaching 26.33 MPa. In the bone, the greatest concentration of stress occurred in the region where the plate was anchored. Our results showed that the 90° hook plate had a superior mechanical performance in fixing simulate lunate facet fractures at the distal radius. This angle led to minor displacements and minimized stress concentrations in the hardware, thus contributing to enhance the stability of this specific fracture.

Indexed as

Bone PlatesFinite Element AnalysisFracture Fixation, InternalRadius FracturesAdultBiomechanical PhenomenaHumansIntra-Articular FracturesModels, AnatomicBiomechanicsDistal radiusFinite Element AnalysisNovel hook plateVolar marginal fractures

Identifiers

PMID39506778
PMCPMC11539762

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.